Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2013492
Status: Closed
Facility Name: Former Ashland Mart Corp.
Address: 1530 W. Lawrence Ave.
Chicago, IL 60642
County: Cook
Property Parcel: 14-08-315-026-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: U003497
Green Tag Issue Date: 12/19/2019
Green Tag Expiration Date: 7/28/2020

Owner Details

Owner Name: GW Lawrence Ashland, LLC
Owner Address: 2211 N. Elston Ave., Suite 304
Chicago, IL 60614
Owner Status: Current Owner
Purchase Date: 10/1/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/10/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/19/2019 12/31/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039767 GW Lawrence Ashland, LLC Current Owner 10/1/2019
U0037639 Ashland Mart Corporation Former Owner 12/3/2014
U0027735 Paitoon Spiratanapaitoon Former Owner 2/1/1998
U0014270 Arta Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
20-0318 4/13/2020 Removal Log 00297-2020REM
20-0318 4/14/2020 Removal Log 00297-2020REM
97-1932 12/1/1997 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-1932 Eligible 10/23/1997 10/29/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/2/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/2/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/2/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/2/1998
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/3/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/3/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/3/1997
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1996 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/13/2020
OSFM First Notify Date: 9/28/1998 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/18/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/14/2017 9/14/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/6/2019 11/6/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/6/2019 11/6/2020
Overfill Prev Device Overfill Drop Tube Valve 12/18/2019 12/18/2022
Piping Flexible Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/14/2018 11/14/2021
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Single Wall Piping Precision Test Pass 11/6/2019



Tank Number 9

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/13/2020
OSFM First Notify Date: 9/28/1998 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/18/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/14/2017 9/14/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/6/2019 11/6/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/6/2019 11/6/2020
Overfill Prev Device Overfill Drop Tube Valve 12/18/2019 12/18/2022
Piping Flexible Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/14/2018 11/14/2021
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Single Wall Piping Precision Test Pass 11/6/2019



Tank Number 10

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/14/2020
OSFM First Notify Date: 9/28/1998 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/18/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/14/2017 9/14/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/6/2019 11/6/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/6/2019 11/6/2020
Overfill Prev Device Overfill Drop Tube Valve 12/18/2019 12/18/2022
Piping Flexible Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/6/2019 11/6/2022
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Single Wall Piping Precision Test Pass 11/6/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms