Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0031875 |
Buckeye Partners |
Current Owner |
10/1/2004 |
| U0027449 |
Equilon Enterprises, LLC |
Former Owner |
7/1/1998 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
1000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Unknown |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
1000 |
|
Petroleum Use: |
Consumptive Use on Premises for Heating |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
8/21/1997 |
|
OSFM
First Notify Date: |
6/12/1986 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
500 |
|
Petroleum Use: |
None |
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
12/21/1989 |
|
OSFM
First Notify Date: |
4/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
44 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
1000 |
|
Petroleum Use: |
|
| Product: |
Hazardous Substance |
|
CERCLA Substance: |
Mixed Hydrocarbon-Solvents |
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
12/21/1989 |
|
OSFM
First Notify Date: |
4/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
40 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 8
| Capacity: |
1000 |
|
Petroleum Use: |
|
| Product: |
Hazardous Substance |
|
CERCLA Substance: |
Mixed Hydrocarbon-Solvents |
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
12/21/1989 |
|
OSFM
First Notify Date: |
4/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
34 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Hazardous Substance |
|
CERCLA Substance: |
Solvents |
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
1/1/1993 |
|
OSFM
First Notify Date: |
5/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
17 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 10
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Waste Oil |
|
CERCLA Substance: |
|
| Status: |
Unknown |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/2/1999 |
|
Abandoned Material: |
|
| Current Age: |
33 |
|
Abandoned Date: |
|
| Install Date: |
11/1/1992 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
12/1/1992 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Gravity Feed |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Sump Sensor |
6/23/2017 |
6/23/2018 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
6/23/2017 |
6/23/2018 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Alarm |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Secondary Containment |
Not applicable |
Not applicable |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Composite Double Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found