Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2012209
Status: Active
Facility Name: Streamwood 76
Address: 1001 W. Irving Park Rd. Streamwood, IL 60120
County: Cook
Property Parcel: 06-21-403-008-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002447
Green Tag Issue Date: 8/29/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Freedom Medical, LLC
Owner Address: 7059 W. 111th Street Suite B Worth, IL 60482
Owner Status: Current Owner
Purchase Date: 3/25/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/4/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/29/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041586 Freedom Medical, LLC Current Owner 3/25/2024
U0040455 IYS Ventures, LLC Former Owner 7/22/2021
U0037337 Lehigh Gas Wholesale Services Former Owner 9/27/2016
U0025164 BAPA, LLC & PT, LLC Former Owner 7/13/2011
U0031542 Alpha Petroleum, Inc. Former Owner 9/2/2003
U0032455 The Premcor Refining Group, Inc. c/o Valero Energy Corporation Former Owner 1/1/1995
U0000651 B.A.P.A., LLC & PT, LLC Former Owner 5/14/1992
U0024983 Clark Refining & Marketing, Inc. Former Owner 11/22/1988
U0011131 Northwest Grocery Marts Inc Former Owner 12/31/1967
U0029789 Clark Retail Enterprises, Inc. Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20230029 Eligible 1/17/2023 1/23/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/18/2025 8/18/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/16/2024 8/16/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/28/2025 8/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2025 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 7/22/2024 7/22/2027
Piping Fiberglass Double Wall N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/22/2024 7/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/22/2024
Piping Steel Single Wall Piping Precision Test (Piping) Pass 8/28/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/17/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/18/2025 8/18/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/16/2024 8/16/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/28/2025 8/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2025 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2024 7/26/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/22/2024 7/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/22/2024
Piping Steel Single Wall Piping Precision Test (Piping) Pass 8/28/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/17/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/18/2025 8/18/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/16/2024 8/16/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/28/2025 8/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2025 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 7/22/2024 7/22/2027
Piping Fiberglass Double Wall N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/22/2024 7/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/22/2024
Piping Steel Single Wall Piping Precision Test (Piping) Pass 8/28/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/17/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms