Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2011839
Status: Active
Facility Name: SNK Fuels/Citgo
Address: 4759 South Cicero Chicago, IL 60632
County: Cook
Property Parcel: 19-10-100-046-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02200
Green Tag Issue Date: 10/28/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: 4759 South Cicero Chicago, LLC
Owner Address: 26 Mill Plain Road Danbury, CT 06811
Owner Status: Current Owner
Purchase Date: 3/20/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/2/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/28/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041477 4759 South Cicero Chicago, LLC Current Owner 3/20/2025
U0032753 Mohammed M. Siddiqui Former Owner 4/1/2004
U0023956 C&N Bros LTD Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0323 5/8/2025 Removal Log 00501-2025REM
2025-0323 5/9/2025 Removal Log 00501-2025REM
21-0623 7/1/2021 Removal Log 00730-2021REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 50 Abandoned Date: 5/7/2025
Install Date: 7/1/1975 Red Tag Issue Date:
Last Used Date: 4/1/2025 Fee Due: $0.00
Product Date: 7/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/19/2024 10/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/19/2024 10/19/2025
Overfill Prev Device Overfill Drop Tube Valve 6/26/2023 6/26/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/26/2023 6/26/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 10/19/2024
Tank Steel Single Wall Precision Test (Tank) Pass 1/12/2023



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 50 Abandoned Date: 5/7/2025
Install Date: 7/1/1975 Red Tag Issue Date:
Last Used Date: 4/1/2025 Fee Due: $0.00
Product Date: 7/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/19/2024 10/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/19/2024 10/19/2025
Overfill Prev Device Overfill Drop Tube Valve 6/26/2023 6/26/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/26/2023 6/26/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 10/19/2024
Tank Steel Single Wall Precision Test (Tank) Pass 1/12/2023



Tank Number 3

Capacity: 8300 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/8/2025
OSFM First Notify Date: 3/22/1990 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: 4/1/2025 Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/19/2024 10/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/19/2024 10/19/2025
Overfill Prev Device Overfill Drop Tube Valve 6/26/2023 6/26/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/26/2023 6/26/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 10/19/2024
Tank Steel Single Wall Precision Test (Tank) Pass 1/12/2023



Tank Number 4

Capacity: 8300 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/9/2025
OSFM First Notify Date: 3/22/1990 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: 4/1/2025 Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/19/2024 10/19/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/19/2024 10/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/19/2024 10/19/2025
Overfill Prev Device Overfill Drop Tube Valve 6/26/2023 6/26/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/26/2023 6/26/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Fail 10/19/2024
Tank Steel Single Wall Precision Test (Tank) Pass 1/12/2023



Tank Number 5

Capacity: 1050 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/2021
OSFM First Notify Date: 3/22/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: 10/28/2015 Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/13/2014 2/13/2015
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/22/2014 2/22/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Ball Float Vent Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 5/29/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2025 10/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/8/2025 10/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/8/2025 10/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/8/2025 10/8/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026
Spill Contain Device Double Wall Spill Bucket 10/8/2025 10/8/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 7/29/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 7/29/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 5/29/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2025 10/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/8/2025 10/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/8/2025 10/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/8/2025 10/8/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026
Spill Contain Device Double Wall Spill Bucket 10/8/2025 10/8/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 7/29/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 7/29/2025



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 5/29/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2025 10/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/8/2025 10/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/8/2025 10/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/8/2025 10/8/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026
Spill Contain Device Double Wall Spill Bucket 10/8/2025 10/8/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 7/29/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 7/29/2025



Tank Number 9

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 5/29/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2025 10/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/8/2025 10/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/8/2025 10/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/8/2025 10/8/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026
Spill Contain Device Double Wall Spill Bucket 10/8/2025 10/8/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 7/29/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 7/29/2025

Dispenser Information



Name\ID 1/2

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028



Name\ID 11/12

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026



Name\ID 3/4

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026



Name\ID 7/8

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/8/2025 10/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2025 10/8/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2011839 SNK Fuels/Citgo Chicago 05/13/2025 Letter Form