Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2011201
Status: Active
Facility Name: Mobil FSZM Corporation
Address: 6000 Oakton Street Morton Grove, IL 60053
County: Cook
Property Parcel: 10-20-302-037-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001088
Green Tag Issue Date: 3/13/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Oaktin Real Estate Company, Inc.
Owner Address: 6000 Oakton Street Morton Grove, IL 60053
Owner Status: Current Owner
Purchase Date: 8/28/2023
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 9/18/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/13/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041598 Oaktin Real Estate Company, Inc. Current Owner 8/28/2023
U0039791 Chicago Title Land Trust Co. Under Trust #52119T Former Owner 12/31/2012
U0009322 Nick & Ernie's, Inc. Former Owner 1/1/1982

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252787 (Pending)    Issue Date: 10/21/2025    Expiration Date: 12/20/2025    View NOV Form

Tanks Violations
4 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed.
4 Line leak detection equipment in alarm or failed test, must repair or replace. - Line leak detection equipment in alarm on ATG; Repair/replace as necessary to clear alarm. L3: North Diesel Sub Pit Fuel Alarm
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and 2 years of documentation maintained on site. 30-Day Walkthrough Inspection form available at www.sfm.illinois.gov. The form must be filled out by an A/B Operator, you must, initial each box that applies, date the form each month to ensure it is being done every 30 days, and the A/B operator must print and sign their name at the bottom. If more than one A/B operator fills out the form, then each must print and sign name at the bottom. 2024 THROUGH OCTOBER 2025, NOT DATED.
1, 3, 4 Monthly impressed current system log not available or maintained. - A log showing the rectifier gauge readings from Impressed Current rectifier shall be maintained monthly on site for review by OSFM Inspector. Log shall show date; amp, volt, indicator lights functionality, and hour meter readings; system status, name of employee who recorded information. NO LOG FOR 2025.
4 Open electrical conduit or junction boxes. - DIESEL ATG PROBE HAS CAP OFF WHICH MAY BE ALLOWING WATER TO GET IN AND COULD BE CAUSING HIGH WATER ALARM.
1, 3, 4 Precision tank test required. - Precision tank test is required on tank(s) if you cannot provide 24 months’ worth of tank “NORMAL” from ATG.
1, 3, 4 Required monthly tank leak test records not available. - Maintain one PASSing report per TANK, per month, from ATG. Must maintain 24 months’ worth.
1, 3, 4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 3 Tank monitor does not appear to function properly and requires maintenance. - Indicator lights on panel of Veeder-Root ATG are not functional. Replace as necessary to provide proper operation. ALL 3 Lights are non-functional.
4 Tank monitor does not appear to function properly and requires maintenance. - ATG in alarm; repair/replace as necessary to secure alarm. T3; High Water Warning. Tank has 59 gallons of water, REMOVE WATER.
4 Tank monitor does not appear to function properly and requires maintenance. - Indicator lights on panel of Veeder-Root ATG are not functional. Replace as necessary to provide proper operation. ALL 3 Lights are non-functional.
1, 3, 4 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP sump(s) contain(s) liquid, creating alarm on ATG. Remove liquid and repair containment to prevent further liquid ingress. Repair/replace sensor(s) as necessary to clear alarm.

NOV Number: E0020252788 (Pending)    Issue Date: 10/21/2025    Expiration Date: 12/20/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.
Facility Fire Extinguishers - 2 4A:60BC extinguishers not provided - Provide min of 2 fire extinguishers (4A:60 BC rated), installed to provide access to both employees and customers.
Facility Fire Extinguishers - Past due for annual testing - Fire extinguishers require annual testing. Have annual testing performed and tag all fire extinguishers accordingly.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-2123 9/13/1999 Removal Log 02353-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-2123 Eligible 6/13/2008 7/17/2008 $10,000
20200430 Eligible 7/13/2020 7/13/2020 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 6/15/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/15/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/9/2025 9/9/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2025 9/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/9/2025 9/9/2026
Overfill Prev Device Overfill Drop Tube Valve 3/11/2024 3/11/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/4/2024 1/4/2027
Leak Detect - Piping Sump Sensor 9/9/2025 9/9/2026
Spill Contain Device Single Wall Spill Bucket 1/4/2024 1/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2025



Tank Number 2

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 44 Abandoned Date: 4/14/2020
Install Date: 6/15/1981 Red Tag Issue Date:
Last Used Date: 5/16/2019 Fee Due: $0.00
Product Date: 6/15/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/2/2018 10/2/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/2/2018 10/2/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve 10/2/2018 10/2/2021
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor 12/6/2019 12/6/2020
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 6/15/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/15/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/9/2025 9/9/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2025 9/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/9/2025 9/9/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2024 2/21/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/4/2024 1/4/2027
Leak Detect - Piping Sump Sensor 9/9/2025 9/9/2026
Spill Contain Device Single Wall Spill Bucket 1/4/2024 1/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2025



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 6/15/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/15/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/9/2025 9/9/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2025 9/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/9/2025 9/9/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2024 2/21/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/4/2024 1/4/2027
Leak Detect - Piping Sump Sensor 9/9/2025 9/9/2026
Spill Contain Device Single Wall Spill Bucket 1/4/2024 1/4/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2025



Tank Number 5

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 9/13/1999
OSFM First Notify Date: 6/30/1992 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/1/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 560 Petroleum Use: Consumptive Use on Premises for Heating
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 9/13/1999
OSFM First Notify Date: 6/30/1992 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/1/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found