Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2011025
Status: Inactive
Facility Name: Sherman Hospital
Address: 934 Center Street
Elgin, IL 60120
County: Kane
Property Parcel: 06-12-152-015
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: T004787
Green Tag Issue Date: 1/17/2018
Green Tag Expiration Date: 12/31/2020

Owner Details

Owner Name: Sherman Hospital
Owner Address: 934 Center Street
Elgin, IL 60120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/5/2019

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013870 Sherman Hospital Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250662 (Pending)    Issue Date: 3/13/2025    Expiration Date: 5/12/2025    View NOV Form

Tanks Violation
1 Failed to Empty the Tank to 1" or Less - Per 175.810(a)(1), when placing tanks out of service, the tank and lines must be emptied immediately. The UST is considered empty when all materials have been removed to one inch or less. As of 10/6/20, this tank had approximately 67 inches of product in the tank. This was confirmed by a stick reading of the tank.
Facility Financial responsibility must be reported yearly - Per 41 Ill. Adm. Code 176.220, tank owners/operators must submit an electronic Financial Responsibility Report form on an annual basis. Financial Responsibility must be maintained until the tank is removed or properly abandoned in place by a licensed UST decommissiong contractor. The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
1 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year - This single wall tank was taken out of service on 8/6/20, and is 44 years old. Per 175.810(e) tank must be removed as it is now condemned. Here is a link to the licensed UST Decommissioning contractors, that can perform UST tank removals: https://webapps.sfm.illinois.gov/ustsearch/ContractorSearch.aspx
Facility Submit Notification Form For Ownership Change - Per 41 Ill. Adm. Code 176.440 (g), a change of ownership information must be reported on an electronic Notification for Underground Storage Tank form, within 30 days of the change. According to DuPage County Illinois, a Special Warranty Deed was recorded on 9/9/19. The Notification Form is available at: https://webapps.sfm.illinois.gov/USTPortal/NotificationForm.
1 Submit Notification Form For Tank Status Change - Per 175.810(a)(3), tanks taken out of service are required to notify the OSFM within 30 days of date of last use, on an electronic Notification for Underground Storage Tank form, declaring a tank status change. This tank was last used on 8/6/20. Here is the link to the electronic Notification for Underground Storage Tank form, so that you can file that change: https://webapps.sfm.illinois.gov/USTPortal/NotificationForm

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 5/1/1980 Red Tag Issue Date: 10/6/2020
Last Used Date: 8/6/2020 Fee Due:
Product Date: 5/5/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/16/2017 10/16/2018
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/16/2017 10/16/2018
Leak Detect - Piping American with Annual Prec Line Testing Suction 10/13/2017 10/13/2018
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Annual Prec Line Testing Suction Functional Pass 10/13/2017



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/2012
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/2012 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Composite Secondary Containment N/A N/A
Corrosion Prot - Tank Lining Materials Internal 1/15/2009 1/15/2014
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 750
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Secondary Containment Copper Primary with Non Corrosive Secondary N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Aboveground CAS Code:
Regulated Status: Exempt Removed Date: 9/20/2012
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found