Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2011003
Status: Inactive
Facility Name: ISTHA M05 Maintenance Garage
Address: Route 90 & Route 53
Northwest Tollway, Mile Post 11
Schaumburg, IL 60008
County: Cook
Property Parcel: 00000000
Facility Type: State
Owner Type: State
Green Tag Decal: Y003991
Green Tag Issue Date: 4/20/2023
Green Tag Expiration Date: 12/2/2024

Owner Details

Owner Name: Illinois State Toll Highway Authority
Owner Address: 2700 Ogden Avenue
Downers Grove, IL 60515
Owner Status: Current Owner
Purchase Date: 1/1/1958
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/31/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007425 Illinois State Toll Highway Authority Current Owner 1/1/1958

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250413 (Referred to Legal)    Issue Date: 2/19/2025    Expiration Date: 4/20/2025    View NOV Form

Tanks Violation
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
92-0516 7/30/1992 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-0516 Eligible 11/22/1994 12/22/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date: 11/15/2024
Last Used Date: 12/1/2023 Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2022 11/21/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/21/2022 11/21/2023
Overfill Prev Device Overfill Alarm 2/10/2023 2/10/2026
Overfill Prev Device Overfill Drop Tube Valve 11/23/2021 11/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/23/2021 11/23/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 11/21/2022 11/21/2023
Leak Detect - Piping Sump Sensor with positive shutdown 4/19/2023 4/19/2024
Spill Contain Device Double Wall Spill Bucket 11/23/2021 11/23/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date: 11/15/2024
Last Used Date: 12/1/2023 Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2022 11/21/2023
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/21/2022 11/21/2023
Overfill Prev Device Overfill Alarm 2/10/2023 2/10/2026
Overfill Prev Device Overfill Drop Tube Valve 11/23/2021 11/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall STP/Tanktop Sump 11/23/2021 11/23/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 11/21/2022 11/21/2023
Leak Detect - Piping Sump Sensor with positive shutdown 4/19/2023 4/19/2024
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/23/2021 11/23/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 300 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/25/1992
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: 2/25/1992 Fee Due: $0.00
Product Date: 1/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 62 Abandoned Date: 1/1/1981
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 62 Abandoned Date: 1/1/1981
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/30/1992
OSFM First Notify Date: 10/22/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: 7/30/1992 Fee Due: $0.00
Product Date: 1/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/23/2021 11/23/2024
Leak Detect - Piping Sump Sensor with positive shutdown 4/19/2023 4/19/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/23/2021 11/23/2024
Leak Detect - Piping Sump Sensor with positive shutdown 4/19/2023 4/19/2024

MFD Motorfuel Dispensing Forms

No Forms Found