Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010854
Status: Active
Facility Name: Harlem & Palmer Mobil
Address: 2144 North Harlem Elmwood Park, IL 60635
County: Cook
Property Parcel: 12-36-223-044-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000081
Green Tag Issue Date: 6/26/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Alfred Karalli
Owner Address: 6840 West Howard Niles, IL 60714
Owner Status: Current Owner
Purchase Date: 9/4/2007
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/13/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/26/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035220 Karalli, Alfred Current Owner 9/4/2007
U0030031 Balagam, Meher Former Owner 2/26/2001
U0023834 BP Amoco Former Owner 4/8/1995
U0027493 Amoco Oil Company Former Owner 1/1/1979
U0000552 BP Products North America, Inc. Former Owner 1/1/1979

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
12-0147 2/23/2012 Abandonment Log 00814-2011ABN
14-0908 8/6/2014 Removal Log 00384-2014REM
14-0909 8/7/2014 Abandonment Log 00386-2014ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
88-0074 Eligible 7/24/1997 8/21/1997 $50,000
12-0147 Eligible 6/6/2014 7/23/2014 $5,000
14-0908 Eligible 5/11/2015 6/3/2015 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 4/26/1988 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/26/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 46 Abandoned Date: 8/7/2014
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/18/2014 2/18/2017
Corrosion Prot - Tank Lining Materials Internal 6/25/2009 6/25/2014
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/18/2014 2/18/2015
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/26/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 46 Abandoned Date: 2/23/2012
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: 6/1/2009 Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 6/25/2009 6/25/2012
Corrosion Prot - Tank Lining Materials Internal 6/25/2009 6/25/2014
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/28/2011 6/28/2012
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/26/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 56 Abandoned Date: 8/7/2014
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/18/2014 2/18/2017
Corrosion Prot - Tank Lining Materials Internal 6/25/2009 6/25/2014
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/18/2014 2/18/2015
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/6/2014
OSFM First Notify Date: 4/26/1988 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 6/25/2009 6/25/2012
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 6/25/2009 6/25/2012
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging N/A N/A
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 14000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/2020 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 7/31/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/26/2025 6/26/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/26/2025 6/26/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/26/2025 6/26/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/2020 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 7/31/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/26/2025 6/26/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/26/2025 6/26/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/26/2025 6/26/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/2020 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 7/31/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/26/2025 6/26/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/26/2025 6/26/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/26/2025 6/26/2026
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/26/2025 6/26/2026

MFD Motorfuel Dispensing Forms