Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010850
Status: Active
Facility Name: BP 15478
Address: 816 St. Charles Street
Elgin, IL 60120
County: Kane
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002716
Green Tag Issue Date: 5/26/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Rocnation, LLC
Owner Address: 816 St. Charles Street
Elgin, IL 60120
Owner Status: Current Owner
Purchase Date: 5/24/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/26/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037902 Rocnation, LLC Current Owner 5/24/2015
U0032360 Angel Associates, LP Former Owner 12/14/2009
U0023834 BP Amoco Former Owner 7/23/1997
U0036719 Route 25, LLC Former Owner
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020251044 (Pending)    Issue Date: 4/16/2025    Expiration Date: 6/15/2025    View NOV Form

Tanks Violation
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Self-service instructional signs at dispensers are missing or do not meet minimum requirements. Install appropriate signage.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.
Facility Fire Extinguishers - Past due for annual testing - Fire extinguishers require annual testing. Have annual testing performed and tag all fire extinguishers accordingly.

NOV Number: E0020251046 (Pending)    Issue Date: 4/16/2025    Expiration Date: 6/15/2025    View NOV Form

Tanks Violation
4, 5, 6 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensors have been raised rendering them ineffective at the regular STP & Dispenser 11/12. Repair/replace sensors into proper location so they can function as designed.
Facility Missing copies of current testing certificates for operator training - Copies of all current Class C testing certificates shall be maintained on file on site. Go to www.sfm.illinois.gov (UST Operator Training) to find current information regarding Operator Training requirements, including all relevant forms.
Facility Missing list of designated Class A/B & C Operators - A comprehensive list of Class A / B / C Operator(s) shall be maintained on site and must be current.
4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
4, 5, 6 Tank monitor does not appear to function properly and requires maintenance. - Indicator lights (YELLOW & GREEN) on panel of Veeder-Root ATG are not functional. Replace as necessary to provide proper operation.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-0543 Eligible 2/5/1999 4/2/1999 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/3/1997
OSFM First Notify Date: 9/28/1987 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/27/1997 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/3/1997
OSFM First Notify Date: 9/28/1987 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/27/1997 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/3/1997
OSFM First Notify Date: 9/28/1987 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/27/1997 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/13/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 7/23/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/23/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/23/2025 4/23/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/23/2025 4/23/2026
Overfill Prev Device Overfill Drop Tube Valve 4/23/2025 4/23/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/23/2025 4/23/2028
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026
Spill Contain Device Single Wall Spill Bucket 4/23/2025 4/23/2028
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/13/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 7/23/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/23/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/23/2025 4/23/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/23/2025 4/23/2026
Overfill Prev Device Overfill Drop Tube Valve 4/23/2025 4/23/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/23/2025 4/23/2028
Leak Detect - Piping Non-Discriminating Sump Sensor 6/23/2020 6/23/2021
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026
Spill Contain Device Single Wall Spill Bucket 4/23/2025 4/23/2028
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/23/2020



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/13/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 7/23/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/23/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/23/2025 4/23/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/23/2025 4/23/2026
Overfill Prev Device Overfill Drop Tube Valve 4/23/2025 4/23/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/21/2022 4/21/2025
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026
Spill Contain Device Single Wall Spill Bucket 4/23/2025 4/23/2028
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 3/1/1987
OSFM First Notify Date: 2/4/1999 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/1/1965 Red Tag Issue Date:
Last Used Date: 1/1/1987 Fee Due:
Product Date: 1/1/1965

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 3/1/1987
OSFM First Notify Date: 2/4/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 3/1/1987
OSFM First Notify Date: 2/4/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/23/2025 4/23/2028
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/23/2025 4/23/2028
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/23/2025 4/23/2028
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/23/2025 4/23/2028
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2022 4/21/2025
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2022 4/21/2025
Leak Detect - Piping Sump Sensor 4/23/2025 4/23/2026

MFD Motorfuel Dispensing Forms

No Forms Found