Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010685
Status: Active
Facility Name: Lake Zurich #3
Address: 1 N. Rand Road Lake Zurich, IL 60047
County: Lake
Property Parcel: 14-18-300-040
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00933
Green Tag Issue Date: 8/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Graham C-Stores Co.
Owner Address: 39109 N. US Hwy 41 Wadsworth, IL 60083
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/18/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0025940 Graham C-Stores Co. Current Owner
U0006038 Graham C-Stores Company Former Owner 7/15/1992
U0002208 Butt Richard Former Owner 12/31/1967
U0027627 Graham C-Stores Co. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-0529 1/29/2001 Removal Log 00089-2001REM
00-0529 3/12/2001 Removal Log 00236-2001REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-0529 Eligible 4/26/2000 5/9/2000 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 6/9/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/9/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/9/2026 6/9/2027
Overfill Prev Device Overfill Alarm 3/13/2026 3/13/2029
Overfill Prev Device Overfill Drop Tube Valve 3/13/2026 3/13/2029
Piping Flexible Double Wall NUPI Smartflex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 3/13/2026 3/13/2029
Spill Contain Device Single Wall Spill Bucket 3/13/2026 3/13/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2022
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 6/9/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/22/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 6/9/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/9/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/9/2026 6/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/9/2026 6/9/2027
Overfill Prev Device Overfill Alarm 3/13/2026 3/13/2029
Overfill Prev Device Overfill Drop Tube Valve 3/13/2026 3/13/2029
Piping Flexible Double Wall NUPI Smartflex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 3/13/2026 3/13/2029
Spill Contain Device Single Wall Spill Bucket 3/13/2026 3/13/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2022
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 6/9/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/22/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 6/9/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/9/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/9/2026 6/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/9/2026 6/9/2027
Overfill Prev Device Overfill Alarm 3/13/2026 3/13/2029
Overfill Prev Device Overfill Drop Tube Valve 3/13/2026 3/13/2029
Piping Flexible Double Wall NUPI Smartflex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 3/13/2026 3/13/2029
Spill Contain Device Single Wall Spill Bucket 3/13/2026 3/13/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2022
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 6/9/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/22/2023



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/12/2001
OSFM First Notify Date: 4/15/2001 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 1/23/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/24/2001

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Ameron Flex III Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 5

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 1/29/2001
OSFM First Notify Date: 1/22/2001 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1970 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2001 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 3/14/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/14/2001

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/9/2026 6/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/9/2026 6/9/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/9/2026 6/9/2027
Overfill Prev Device Overfill Alarm 3/13/2026 3/13/2029
Overfill Prev Device Overfill Drop Tube Valve 3/13/2026 3/13/2029
Piping Flexible Double Wall NUPI Smartflex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 3/13/2026 3/13/2029
Spill Contain Device Single Wall Spill Bucket 3/13/2026 3/13/2029
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2022
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 6/9/2026
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 2/22/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2026 3/13/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2026 6/9/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found