Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010522
Status: Active
Facility Name: 802 West Palatine, LLC
Address: 802 W. Palatine Road Palatine, IL 60067
County: Cook
Property Parcel: 02-16-412-013-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000028
Green Tag Issue Date: 4/17/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: 802 West Palatine, LLC
Owner Address: 26 Mill Plain Road Danbury, CT 06811
Owner Status: Current Owner
Purchase Date: 9/15/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/2/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041011 802 West Palatine, LLC Current Owner 9/15/2023
U0038573 Palatine Land, LLC Former Owner 3/12/2016
U0032420 Quentin & Palatine Citgo, Inc. Former Owner 9/30/2004
U0027042 TGS New Enterprises Limited, LLC Former Owner 11/11/1998
U0025970 PDV Midwest Refining Llc Former Owner 5/1/1997
U0015441 The Uno Ven Company Former Owner 4/5/1993
U0029182 Palatine Citgo Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261759 (Pending)    Issue Date: 7/9/2026    Expiration Date: 9/7/2026    View NOV Form

Tanks Violations
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Replace steel ring and STPlid. Rusted and not seating properly.
2, 3, 4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Remove Liquid
2, 3, 4 Tank monitor does not appear to function properly and requires maintenance. - Green indicator light is out and needs to be replaced.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-0357 Returned 10/18/2004 10/27/2004 $Not Selected
92-0357 Eligible 4/22/2013 6/7/2013 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/8/2002
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1999 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/22/2026 1/22/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/22/2026 1/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 1/22/2026 1/22/2027
Overfill Prev Device Overfill Drop Tube Valve 2/5/2024 2/5/2027
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 1/31/2024 1/31/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 1/22/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/2/2024



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 58 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/22/2026 1/22/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/22/2026 1/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 1/22/2026 1/22/2027
Overfill Prev Device Overfill Drop Tube Valve 2/13/2024 2/13/2027
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 1/31/2024 1/31/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 1/22/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 1/31/2024



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 58 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/22/2026 1/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 1/22/2026 1/22/2027
Overfill Prev Device Overfill Drop Tube Valve 1/31/2024 1/31/2027
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/19/2024 3/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2027
Spill Contain Device Single Wall Spill Bucket 1/31/2024 1/31/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/7/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/7/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2024 3/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 1/22/2026 1/22/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found