Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009885
Status: Active
Facility Name: OM Sainath Oil, Inc.
Address: 96 N. La Fox Street
South Elgin, IL 60177
County: Kane
Property Parcel: 06-35-158-006-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003257
Green Tag Issue Date: 8/10/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: OM Sainath Oil, Inc.
Owner Address: 96 N La Fox Street
South Elgin, IL 60177
Owner Status: Current Owner
Purchase Date: 9/28/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/25/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/31/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037124 OM Sainath Oil, Inc. Current Owner 9/28/2023
U0040958 DAJA Gas Station, LLC Former Owner 5/24/2022
U0040135 AANYA, LLC Former Owner 12/10/2020
U0037165 Haj Petroleum, Inc. Former Owner 2/13/2012
U0033680 Bestway Petroleum, Inc. Former Owner 9/1/2004
U0031497 Ridge Lane Associates Former Owner 8/28/2003
U0003073 Clark Retail Enterprises, Inc. Former Owner 11/22/1988
U0029789 Clark Retail Enterprises, Inc. Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250370 (Pending)    Issue Date: 2/13/2025    Expiration Date: 4/14/2025    View NOV Form

Tanks Violation
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

NOV Number: E0020250371 (Pending)    Issue Date: 2/13/2025    Expiration Date: 4/14/2025    View NOV Form

Tanks Violation
4 Line leak detection equipment in alarm or failed test, must repair or replace. - Periodic line test failure (0.2 gal/hr). Repair/replace as necessary to achieve passing test. Has been failing since 2/8/2025.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website.
Facility Missing copy of written UST facility operation & maintenance plan - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available at www.sfm.illinois.gov to download and complete O & M template and maintain completed form on site.
4 Tank monitor does not appear to function properly and requires maintenance. - ATG in alarm; repair/replace as necessary to secure alarm.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-2266 8/24/1993 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-2266 Eligible 1/10/1994 1/21/1994 $10,000
93-2266 Eligible 4/15/2003 4/22/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/1993
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 8/22/1993 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/1993
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 8/22/1993 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/18/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 8/25/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/25/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/28/2022 4/28/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/26/2024 6/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/26/2024 6/26/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/20/2022 4/20/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/20/2022 4/20/2025
Tank Composite Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/26/2024
Tank Composite Single Wall Precision Test (Tank) Pass 7/10/2024



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/18/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 8/25/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/25/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/28/2022 4/28/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/26/2024 6/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/26/2024 6/26/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/20/2022 4/20/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/20/2022 4/20/2025
Tank Composite Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/26/2024
Tank Composite Single Wall Precision Test (Tank) Pass 7/10/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found