Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009069
Status: Active
Facility Name: California-Peterson Citgo
Address: 2758 W. Peterson Street
Chicago, IL 60659
County: Cook
Property Parcel: 13-01-224-015-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002422
Green Tag Issue Date: 8/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Mahal Management, Inc.
Owner Address: 2758 W. Peterson Street
Chicago, IL 60659
Owner Status: Current Owner
Purchase Date: 12/3/2020
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/1/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040097 Mahal Management, Inc. Current Owner 12/3/2020
U0010471 Exxon Mobil Oil Corporation Former Owner 1/1/1967
U0018980 Tienchai, Amphol Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
94-1972 10/12/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-1972 Eligible 9/7/2001 9/27/2001 $10,000
92-0869 Eligible 9/7/2001 9/27/2001 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 12/11/2017
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: 8/1/2011 Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/22/2024 7/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/22/2024 7/22/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 6/22/2022 6/22/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 7/22/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/14/2020



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/22/2024 7/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/22/2024 7/22/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 6/22/2022 6/22/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 7/22/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/14/2020



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/12/1994
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: 10/1/1994 Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/2002 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 12/11/2017
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: 2/29/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 6/2/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/6/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/22/2024 7/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/22/2024 7/22/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/22/2024 7/22/2025
Overfill Prev Device Overfill Drop Tube Valve 6/22/2022 6/22/2025
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/15/2022 6/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2024 7/22/2025
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 7/22/2024
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 6/22/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5-6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/15/2022 6/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2024 7/22/2025



Name\ID 5/6

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2009069 California-Peterson Citgo Chicago 06/19/2022 Letter Form