Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009014
Status: Active
Facility Name: Arlington Heights Mobil, LLC
Address: 1880 S. Arlington Heights Rd. Arlington Heights, IL 60005
County: Cook
Property Parcel: 08-09-400-054-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02451
Green Tag Issue Date: 10/29/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Chemman Properties, LLC
Owner Address: 1880 S. Arlington Heights Rd. Arlington Heights, IL 60005
Owner Status: Current Owner
Purchase Date: 12/21/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/6/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036751 Chemman Properties, LLC Current Owner 12/21/2012
U0036013 Buchanan Energy (N), LLC Former Owner 12/9/2010
U0010471 ExxonMobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0454 5/5/2011 Removal Log 00295-2011REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-0685 Eligible 5/8/2006 6/2/2006 $10,000
11-0454 Eligible 7/25/2011 9/23/2011 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/2011
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1981 Red Tag Issue Date:
Last Used Date: 5/4/2011 Fee Due: $0.00
Product Date: 6/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/19/2009 1/19/2010
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve Environ FW 3210 No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 1/19/2009



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/2011
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1981 Red Tag Issue Date:
Last Used Date: 5/4/2011 Fee Due: $0.00
Product Date: 6/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/19/2009 1/19/2010
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve Environ FW 3210 No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 1/19/2009



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/2011
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1981 Red Tag Issue Date:
Last Used Date: 5/4/2011 Fee Due: $0.00
Product Date: 6/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/19/2009 1/19/2010
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve Environ FW 3210 No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 1/19/2009



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/2011
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 6/1/1984 Red Tag Issue Date:
Last Used Date: 5/4/2011 Fee Due: $0.00
Product Date: 6/1/1984

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/19/2009 1/19/2010
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve Environ FW 3210 No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 1/19/2009



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/2011
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 6/1/1981 Red Tag Issue Date:
Last Used Date: 5/4/2011 Fee Due: $0.00
Product Date: 6/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Pressurized Line Leak Detection 1/19/2009 1/19/2010
Leak Detect - Tank Automatic Tank Gauging No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Manhole Field Constructed No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/27/2011 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 5/12/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/2011

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/30/2026 7/30/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/30/2026 7/30/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/30/2026 7/30/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/26/2025 3/26/2028
Spill Contain Device Double Wall Spill Bucket 6/11/2025 6/11/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/27/2011 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 5/12/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/2011

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/30/2026 7/30/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/30/2026 7/30/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/30/2026 7/30/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/26/2025 3/26/2028
Spill Contain Device Double Wall Spill Bucket 6/11/2025 6/11/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 8

Capacity: 8000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/27/2011 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 5/12/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/2011

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/30/2026 7/30/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/30/2026 7/30/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/30/2026 7/30/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/26/2025 3/26/2028
Spill Contain Device Double Wall Spill Bucket 6/11/2025 6/11/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor 7/30/2026 7/30/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor 7/30/2026 7/30/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor 7/30/2026 7/30/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor 7/30/2026 7/30/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found