Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2008090
Status:
Closed
Facility Name:
2001 Oil Company
Address:
8001 Golf Road
Niles, IL 60648
County:
Cook
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
I000883
Green Tag Issue Date:
3/16/2007
Green Tag Expiration Date:
12/31/2009
Owner Details
Owner Name:
2001 Oil Company
Owner Address:
5333 Birchwood Avenue
Skokie, IL 60077
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
10/29/2008
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0010331
2001 Oil Company
Current Owner
U0005656
Gas Go Oil Co
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
08-0626
5/7/2008
Removal Log
00442-2008REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
08-0262
Eligible
9/9/2008
9/11/2008
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
13
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
13
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
13
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
13
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
500
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
10/29/1990
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/7/2008
OSFM
First Notify Date:
8/11/1989
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
8/1/1989
Red Tag Issue Date:
Last Used Date:
6/25/2002
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection with Dielectric Coating Bonding additional sacrificial anodes to STI P3 tank
Leak Detect - Tank
Automatic Tank Gauging
Piping
Double Wall steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
2000
Petroleum Use:
Product:
Racing Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/7/2008
OSFM
First Notify Date:
8/11/1989
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
8/1/1989
Red Tag Issue Date:
Last Used Date:
6/25/2002
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Double Wall steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/7/2008
OSFM
First Notify Date:
8/11/1989
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
8/1/1989
Red Tag Issue Date:
Last Used Date:
6/25/2002
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Double Wall steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/7/2008
OSFM
First Notify Date:
8/11/1989
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
8/1/1989
Red Tag Issue Date:
Last Used Date:
6/25/2002
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Double Wall steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/7/2008
OSFM
First Notify Date:
8/11/1989
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
8/1/1989
Red Tag Issue Date:
Last Used Date:
6/25/2002
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found