Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2007970
Status: Active
Facility Name: Wheeling CO
Address: 50 East Dundee Road
Wheeling, IL 60090
County: Cook
Property Parcel:
Facility Type: Utility
Owner Type: Private
Green Tag Decal: X003231
Green Tag Issue Date: 10/4/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: AT&T Corp. d/b/a Illinois Bell
Owner Address: 308 S. Akard, Room 1700
Dallas, TX 75202
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/12/2024

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034340 AT&T Corp. d/b/a Illinois Bell Current Owner
U0007227 Ameritech d/b/a AT&T Former Owner 1/1/1985
U0031962 IL Bell Telephone Co. d/b/a SBC Illinois Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
90-3568 11/30/1990 Removal Log

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8300 Petroleum Use: Consumptive Use on Premises for Heating
Product: Fuel Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 11/30/1990
OSFM First Notify Date: 4/2/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/16/1997 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 8/6/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 1/11/2024 1/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/11/2024 1/11/2025
Overfill Prev Device Overfill Alarm 1/23/2023 1/23/2026
Piping Steel Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/11/2024 1/11/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 2/11/2022 2/11/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/29/2023 9/29/2026
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors Sensor Functional Pass 5/3/2010
Leak Detect - Piping Sump Sensor Sensor Functional Pass 5/3/2010

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found