Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2007696
Status:
Active
Facility Name:
Lindahl Brothers, Inc.
Address:
622 East Green Street
Bensenville, IL 60106
County:
Du Page
Property Parcel:
Facility Type:
Industrial / Manufacturing
Owner Type:
Private
Green Tag Decal:
Y003688
Green Tag Issue Date:
12/13/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Lindahl Brothers, Inc.
Owner Address:
622 East Green Street
Bensenville, IL 60106
Owner Status:
Current Owner
Purchase Date:
1/1/1986
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
1/29/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
5/11/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0009190
Lindahl Brothers, Inc.
Current Owner
1/1/1986
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
98-0353
Eligible
6/5/1998
6/26/1998
$15,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
3000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/22/1989
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
5/21/1989
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
3000
Petroleum Use:
Product:
Motor Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
54
Abandoned Date:
9/22/2011
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
12/23/2009
12/23/2010
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
2000
Petroleum Use:
Product:
Hydraulic Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
54
Abandoned Date:
9/22/2011
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
12/23/2009
12/23/2010
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
1000
Petroleum Use:
Product:
Hydraulic Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
54
Abandoned Date:
9/22/2011
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
12/23/2009
12/23/2010
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
2/18/1998
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
2/17/1998
Fee Due:
$0.00
Product Date:
1/1/1976
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/27/1989
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
4/26/1989
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/27/1989
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
4/26/1989
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/27/1989
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
4/26/1989
Fee Due:
$0.00
Product Date:
1/1/1971
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/22/1997
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
5/31/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/31/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
5/1/2024
5/1/2027
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2024
5/1/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Alarm
6/15/2023
6/15/2026
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
8/1/2024
8/1/2027
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/22/1997
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
5/31/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/31/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
5/1/2024
5/1/2027
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2024
5/1/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Alarm
6/15/2023
6/15/2026
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
8/1/2024
8/1/2027
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 11
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/22/1997
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
5/31/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/31/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
5/1/2024
5/1/2027
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2024
5/1/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Alarm
6/15/2023
6/15/2026
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
8/1/2024
8/1/2027
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 12
Capacity:
5000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/22/1997
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
5/31/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/31/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
5/1/2024
5/1/2027
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2024
5/1/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Alarm
6/15/2023
6/15/2026
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
8/1/2024
8/1/2027
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 13
Capacity:
600
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/8/1998
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
5/31/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/31/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
8/1/2024
8/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
8/1/2024
8/1/2025
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
8/1/2024
8/1/2027
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 2/3
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 4/5
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 6/7
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
MFD
Motorfuel Dispensing Forms