Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2007677
Status: Inactive
Facility Name: Gamboas Citgo
Address: 19200 South Wolf Road
Mokena, IL 60448
County: Will
Property Parcel: 19-09-08-112-042-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: T002652
Green Tag Issue Date: 5/10/2018
Green Tag Expiration Date: 9/24/2020

Owner Details

Owner Name: Robert Gamboa
Owner Address: 19200 S. Wolf Road
Mokena, IL 60448
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/30/2020

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/10/2018 12/31/2020

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0005619 Gamboa , Robert Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020202795 (Referred to Legal)    Issue Date: 9/28/2020    Expiration Date: 11/27/2020    View NOV Form

Tanks Violation
Facility Financial responsibility must be reported yearly
1, 2, 4, 5 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 7/1/1975 Red Tag Issue Date: 2/4/2020
Last Used Date: 8/31/2019 Fee Due: $0.00
Product Date: 7/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/20/2017 1/20/2020
Corrosion Prot - Tank Lining Materials Internal 7/31/2018 7/31/2023
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/27/2017 11/27/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 7/1/1975 Red Tag Issue Date: 2/4/2020
Last Used Date: 8/31/2019 Fee Due: $0.00
Product Date: 7/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/20/2017 1/20/2020
Corrosion Prot - Tank Lining Materials Internal 7/31/2018 7/31/2023
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/27/2017 11/27/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/2/1985
OSFM First Notify Date: 4/18/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date: 2/4/2020
Last Used Date: 8/31/2019 Fee Due: $0.00
Product Date: 12/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/20/2017 1/20/2020
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/27/2017 11/27/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date: 2/4/2020
Last Used Date: 8/31/2019 Fee Due: $0.00
Product Date: 12/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/20/2017 1/20/2020
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information