Facility Details
Facility Number:
2007050
Status:
Active
Facility Name:
Tumara Food Mart Inc.(Citgo)
Address:
2941 E. 83rd Street Chicago, IL 60617
County:
Cook
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z002339
Green Tag Issue Date:
5/14/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Minhaj Ahmed
Owner Address:
5875 N. Lincolnwood, Suite 130 Chicago, IL 60659
Owner Status:
Current Owner
Purchase Date:
4/28/2000
Type of Financial Responsibility:
Certificate of Deposit
Financial Responsibility Reporting Due Date:
4/6/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
5/14/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0029148
Ahmed, Minhaj
Current Owner
4/28/2000
U0027449
Equilon Enterprises, LLC
Former Owner
1/1/1978
U0013849
Shell Oil Products
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
00-1056
6/6/2000
Removal Log
105608
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
87-0047
Eligible
7/24/1998
8/25/1998
$50,000
00-1055
Eligible
7/27/2000
8/3/2000
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
9438
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/6/2000
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
9438
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/6/2000
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
9438
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/6/2000
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/21/2000
Abandoned Material:
Current Age:
25
Abandoned Date:
Install Date:
7/13/2000
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/14/2025
4/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300 with CSLD
4/14/2025
4/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/2/2023
3/2/2026
Piping
Flexible Double Wall Total Containment Omniflex II
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/2/2023
3/2/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex II
Precision Test (Piping)
Pass
4/14/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
12/10/2019
Tank Number 5
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/21/2000
Abandoned Material:
Current Age:
25
Abandoned Date:
Install Date:
7/13/2000
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/14/2025
4/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300 with CSLD
4/14/2025
4/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/2/2023
3/2/2026
Piping
Flexible Double Wall Total Containment Omniflex II
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/2/2023
3/2/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex II
Precision Test (Piping)
Pass
4/14/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
12/10/2019
Tank Number 6
Capacity:
4000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/21/2000
Abandoned Material:
Current Age:
25
Abandoned Date:
Install Date:
7/13/2000
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/14/2025
4/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300 with CSLD
4/14/2025
4/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/7/2023
4/7/2026
Piping
Flexible Double Wall Total Containment Omniflex II
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
4/7/2023
4/7/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex II
Precision Test (Piping)
Pass
4/14/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
12/10/2019
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/5
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2024
4/15/2027
Leak Detect - Piping
Sump Sensor
4/14/2025
4/14/2026
Name\ID 4/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 7/9
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2024
4/15/2027
Leak Detect - Piping
Sump Sensor
4/14/2025
4/14/2026
Name\ID 8/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2024
4/15/2027
Leak Detect - Piping
Sump Sensor
4/14/2025
4/14/2026
MFD
Motorfuel Dispensing Forms
No Forms Found