Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2007042
Status: Active
Facility Name: KJJ Enterprises, Inc.
Address: 11100 Corliss
Chicago, IL 60628
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002064
Green Tag Issue Date: 5/3/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: KJS Properties, LLC
Owner Address: 1535 W. Grand Ave.
Chicago, IL 60642
Owner Status: Current Owner
Purchase Date: 6/2/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/7/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/1/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038329 KJS Properties, LLC Current Owner 6/2/2015
U0035735 True North Energy, LLC Former Owner 3/8/2010
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1973
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250473 (Pending)    Issue Date: 2/25/2025    Expiration Date: 4/26/2025    View NOV Form

Tanks Violation
1 Line interstitial sensors have been raised and rendered inoperational. - Lower Sensor in Regular STP Sump
1, 2, 3 Line leak detection equipment in alarm or failed test, must repair or replace. - Gross Line Fail Alarm and PLLD Shutdown Alarm
1 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Remove water from Regular STP Sump

NOV Number: E0020250474 (Pending)    Issue Date: 2/25/2025    Expiration Date: 4/26/2025    View NOV Form

Tanks Violation
Facility Fire Extinguishers - Past due for annual testing

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-0919 Eligible 2/9/2009 3/10/2009 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/1/2023 5/1/2028
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/19/2025 2/19/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/19/2025 2/19/2026
Overfill Prev Device Overfill Drop Tube Valve 2/28/2023 2/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/28/2023 2/28/2026
Leak Detect - Piping Stand Alone Sump Sensor Non-Discriminating 3/16/2021 3/16/2022
Leak Detect - Piping Sump Sensor with positive shutdown 2/19/2025 2/19/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/28/2023 2/28/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/19/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/2/2023



Tank Number 2

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/1/2023 5/1/2028
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/19/2025 2/19/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/19/2025 2/19/2026
Overfill Prev Device Overfill Drop Tube Valve 2/28/2023 2/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/28/2023 2/28/2026
Leak Detect - Piping Stand Alone Sump Sensor Non-Discriminating 3/16/2021 3/16/2022
Leak Detect - Piping Sump Sensor with positive shutdown 2/19/2025 2/19/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/28/2023 2/28/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/19/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/2/2023



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/1/2023 5/1/2028
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/19/2025 2/19/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/19/2025 2/19/2026
Overfill Prev Device Overfill Drop Tube Valve 2/28/2023 2/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/19/2025 2/19/2026
Spill Contain Device Single Wall Spill Bucket 2/28/2023 2/28/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/19/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/2/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/28/2023 2/28/2026
Leak Detect - Piping Sump Sensor 2/19/2025 2/19/2026

MFD Motorfuel Dispensing Forms