Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006986
Status: Active
Facility Name: Circle K #6763
Address: 1851 N. Farnsworth
Aurora, IL 60507
County: Kane
Property Parcel: 15-12-101-005
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003374
Green Tag Issue Date: 12/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1970
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250708 (Pending)    Issue Date: 3/18/2025    Expiration Date: 5/17/2025    View NOV Form

Tanks Violation
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - 175.220 a) Minimum signage requires letters shall not be less than 7/8” in height. The top of the sign shall be mounted no higher than 10’ above grade. The wording shall include a minimum of 1) “Warning” 2) “Stop Engine” 3) “No Smoking” 4) “Persons fueling vehicles shall remain with their vehicle, at the nozzle, while fueling is in progress” 5) “It is unlawful and dangerous for anyone to dispense gasoline into unapproved containers”

NOV Number: E0020250710 (Pending)    Issue Date: 3/18/2025    Expiration Date: 5/17/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2, 3 Dispensers - hoses cracked, split or worn and require replacement - Replace main hose.
Facility Facility Operation and Maintenance Plan not updated to new requirements. - Operations and Maintenance Template needs to be updated and kept on site.
1, 2, 3 Line interstitial sensors have been raised and rendered inoperational. - All dispensers Section 175.640 a)2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures Plan needs to be updated and kept on site.
1, 2, 3 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-1868 10/8/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1073 Eligible 10/1/2008 10/29/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 10/8/2024 10/8/2029
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/18/2024 12/18/2025
Overfill Prev Device Overfill Drop Tube Valve 3/13/2024 3/13/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/25/2024 1/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 2/16/2021 2/16/2022
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025
Spill Contain Device Single Wall Spill Bucket 1/25/2024 1/25/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/9/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/10/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 10/8/2024 10/8/2029
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/18/2024 12/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/18/2024 12/18/2025
Overfill Prev Device Overfill Drop Tube Valve 1/9/2024 1/9/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/25/2024 1/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 2/16/2021 2/16/2022
Leak Detect - Piping Non-Discriminating Sump Sensor 3/18/2021 3/18/2022
Leak Detect - Piping Discriminating Sump Sensor with positive shutdown 1/27/2022 1/27/2023
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025
Spill Contain Device Single Wall Spill Bucket 1/25/2024 1/25/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 12/18/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/10/2024



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 55 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 10/8/2024 10/8/2029
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/18/2024 12/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/18/2024 12/18/2025
Overfill Prev Device Overfill Drop Tube Valve 3/13/2024 3/13/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/25/2024 1/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 1/27/2022 1/27/2023
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025
Spill Contain Device Single Wall Spill Bucket 1/25/2024 1/25/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 12/18/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/10/2024



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/1996
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: 9/15/1996 Fee Due: $0.00
Product Date: 1/1/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Fuel Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/8/1996
OSFM First Notify Date: 12/12/1996 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/25/2024 1/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/25/2024 1/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/25/2024 1/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/25/2024 1/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/18/2024 12/18/2025

MFD Motorfuel Dispensing Forms

No Forms Found