Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006973
Status: Active
Facility Name: Circle K #6880
Address: 6798 W. 159th Street Oak Forest, IL 60477
County: Cook
Property Parcel: 28-18-401-006-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003065
Green Tag Issue Date: 10/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 9/3/1998
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00775-2025UPG Upgrade Approved / Issued 6/23/2025 6/24/2025 12/24/2025 Documents
00762-2025REM Removal Approved / Issued 6/23/2025 6/23/2025 12/23/2025 Documents
01083-2025REM Removal Approved / Issued 8/19/2025 8/19/2025 2/19/2026 Documents
00244-2025UPG Upgrade Cancelled by Contractor 3/3/2025 3/3/2025 9/3/2025 Documents

Notice of Violatlions (Current)

NOV Number: E0020250507 (Pending)    Issue Date: 2/27/2025    Expiration Date: 8/31/2025    View NOV Form

Tanks Violations
5, 6, 7 Piping interstitial must be open in all sumps - Product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. 175.420 b) (All STPs)
5 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Triennial testing for qualifying STP piping containment sump failed test. Repair/replace as necessary to pass retesting of sump. (Regular STP failed test on 12/2/2024)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 8/19/2025 Emergency Response

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
87-0858 Eligible 10/12/1995 12/11/1995 $50,000
19870858 Eligible 5/19/2020 5/21/2020 $50,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 9887 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/1993
OSFM First Notify Date: 10/9/1987 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 9887 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/1993
OSFM First Notify Date: 10/9/1987 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 7734 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/1993
OSFM First Notify Date: 10/9/1987 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/9/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/15/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/21/1993 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 5/7/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 6/4/2025 6/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 7/19/2024 7/19/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 2/11/2022 12/2/2024
Leak Detect - Piping Sump Sensor 6/4/2025 6/4/2026
Spill Contain Device Double Wall Spill Bucket 6/11/2024 6/11/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/4/2025



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/21/1993 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 5/7/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 6/4/2025 6/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 7/19/2024 7/19/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 12/2/2024 12/2/2027
Leak Detect - Piping Sump Sensor 6/4/2025 6/4/2026
Spill Contain Device Single Wall Spill Bucket 6/11/2024 6/11/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/4/2025



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/21/1993 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 5/7/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2025 6/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 6/4/2025 6/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/4/2025 6/4/2026
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall Transition Sump 12/2/2024 12/2/2027
Leak Detect - Piping Sump Sensor 6/4/2025 6/4/2026
Spill Contain Device Double Wall Spill Bucket 6/11/2024 6/11/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/4/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms