Facility Details
Facility Number:
2006639
Status:
Active
Facility Name:
Carpentersville Transportation
Address:
300 Cleveland Avenue
Carpentersville, IL 60110
County:
Kane
Property Parcel:
Facility Type:
School/College
Owner Type:
Other Local
Green Tag Decal:
Y003948
Green Tag Issue Date:
4/18/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Community Unit School District 300
Owner Address:
2550 Harnish Dr.
Carpentersville, IL 60110
Owner Status:
Current Owner
Purchase Date:
6/1/1986
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
2/20/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
4/18/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0024138
Community Unit School District 300
Current Owner
6/1/1986
U0013600
Community Unit School District 300
Former Owner
3/18/1999
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
03-0940
6/26/2003
Removal Log
02668-2003REM
98
8/5/1998
Removal Log
2676-98
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
98-0633
Eligible
11/19/1998
1/6/1999
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/5/1998
OSFM
First Notify Date:
3/19/1986
Abandoned Material:
Current Age:
19
Abandoned Date:
Install Date:
1/1/1979
Red Tag Issue Date:
Last Used Date:
8/5/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/5/1998
OSFM
First Notify Date:
3/19/1986
Abandoned Material:
Current Age:
17
Abandoned Date:
Install Date:
1/1/1981
Red Tag Issue Date:
Last Used Date:
8/5/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/19/1998
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
8/10/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/31/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS - 4c
3/12/2025
3/12/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/12/2025
3/12/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/12/2025
3/12/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/28/2024
3/28/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
3/12/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
3/12/2025
Tank Number 4
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/19/1998
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
8/10/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/31/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS - 4c
3/12/2025
3/12/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/12/2025
3/12/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/12/2025
3/12/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/28/2024
3/28/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
3/12/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
3/12/2025
Tank Number 5
Capacity:
10000
Petroleum Use:
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
6/26/2003
OSFM
First Notify Date:
7/28/2003
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found