Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2005726
Status: Closed
Facility Name: Nels J Johnson Tree Experts Inc
Address: 912 Pitner Ave
Evanston, IL 60202
County: Cook
Property Parcel: 10-24-120-011-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: S002797
Green Tag Issue Date: 8/15/2017
Green Tag Expiration Date: 12/31/2019

Owner Details

Owner Name: Nels J Johnson Tree Experts Inc
Owner Address: 912 Pitner Ave
Evanston, IL 60202
Owner Status: Current Owner
Purchase Date: 3/24/1981
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 6/14/2020

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/15/2017 12/31/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010905 Nels J Johnson Tree Experts Inc Current Owner 3/24/1981

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2021-0169 2/23/2021 Removal Log 01765-2020REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20210169 Eligible 5/7/2021 5/10/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 3000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/23/2021
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 3/17/1986 Red Tag Issue Date:
Last Used Date: 9/30/2019 Fee Due: $0.00
Product Date: 3/17/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/13/2017 9/13/2022
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found