Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2005467
Status: Active
Facility Name: Little Company of Mary Hospital
Address: 2800 W. 95th Street
Evergreen Park, IL 60805
County: Cook
Property Parcel: 24-01-328-005-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: Z002657
Green Tag Issue Date: 10/28/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Little Company of Mary Hospital
Owner Address: 2800 W. 95th Street
Evergreen Park, IL 60805
Owner Status: Current Owner
Purchase Date: 2/2/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/23/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009250 Little Company of Mary Hospital Current Owner 2/2/2012

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0972 9/1/2010 Removal Log 00375-2010REM
10-0972 8/31/2010 Removal Log 00375-2010REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/1/1988
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 43 Abandoned Date: 10/1/1976
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1976 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8200 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/2010
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Tank Impressed Current Cathodic Protection
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/31/2010
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 6/14/2024 6/14/2025
Overfill Prev Device Overfill Alarm 7/8/2024 7/8/2027
Piping Flexible Double Wall OmegaFlex DoubleTrac N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 9/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/14/2024



Tank Number 7

Capacity: 10000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 8200 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 20000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 35000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/24/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 2/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/17/2024 9/17/2025
Overfill Prev Device Overfill Alarm 5/30/2023 5/30/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2023 5/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor 9/17/2024 9/17/2025
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2022 7/22/2023
Leak Detect - Piping Sump Sensor 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/17/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/11/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/12/2024



Tank Number 11

Capacity: 35000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/24/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 2/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/17/2024 9/17/2025
Overfill Prev Device Overfill Alarm 5/30/2023 5/30/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2023 5/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2022 7/22/2023
Leak Detect - Piping Sump Sensor 9/17/2024 9/17/2025
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor 6/14/2024 6/14/2025
Leak Detect - Piping Sump Sensor 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/17/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/11/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/19/2024

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found