Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2004976
Status: Installed/Not in Use
Facility Name: Speedway #7421
Address: 2420 Plainfield Road Crest Hill, IL 60403
County: Will
Property Parcel: 06-03-25-422-024-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001930
Green Tag Issue Date: 2/28/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500 Springfield, OH 45501
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner
U0016241 Emro Marketing Co Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00359-2026INS Install Extension Granted 4/1/2026 4/1/2026 4/1/2027 Documents
00355-2026REM Removal Extension Granted 4/1/2026 4/1/2026 4/1/2027 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/16/2026
OSFM First Notify Date: 9/15/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2026 8/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/18/2024 5/18/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/16/2026
OSFM First Notify Date: 9/15/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2026 8/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/18/2024 5/18/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/16/2026
OSFM First Notify Date: 9/15/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/18/2024 5/18/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/16/2026
OSFM First Notify Date: 9/15/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2026 8/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/18/2024 5/18/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 5

Capacity: 8000 Petroleum Use: Back-up Generator
Product: B-11 CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/16/2026
OSFM First Notify Date: 9/15/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2026 8/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/18/2024 5/18/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2004976 Speedway #7421 Crest Hill 04/01/2026 Letter Form