Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2003646
Status: Active
Facility Name: Addison Township Highway Department
Address: 411 West Potter Street Wood Dale, IL 60191
County: Du Page
Property Parcel:
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: BB04189
Green Tag Issue Date: 3/10/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Addison Township Highway Department
Owner Address: 411 West Potter Street Wood Dale, IL 60191
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 10/23/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0000214 Addison Township Highway Department Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
92-2628 9/18/1992 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-2628 Eligible 9/23/1994 10/11/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/1/1988
OSFM First Notify Date: 3/19/1986 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 9/1/1979 Red Tag Issue Date:
Last Used Date: 6/1/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/18/1992
OSFM First Notify Date: 3/19/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 7/1/1992 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/28/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 6/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 8/10/2026 8/10/2027
Overfill Prev Device Overfill Drop Tube Valve 8/13/2025 8/13/2028
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 11/13/2020 11/13/2023
Spill Contain Device Double Wall Spill Bucket 8/13/2025 8/13/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 12/30/2019
Tank Fiberglass Single Wall Precision Test (Tank) Pass 12/30/2019



Tank Number 4

Capacity: 2500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/28/2010
OSFM First Notify Date: 7/2/1993 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/2/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/1993

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c No passing test found No passing test found

Additional Tests

No Tests Listed




Tank Number 5

Capacity: 2500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/2010 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 11/1/2010 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 11/24/2010

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 8/10/2026 8/10/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/18/2026 8/18/2027
Overfill Prev Device Overfill Drop Tube Valve 8/13/2025 8/13/2028
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 11/13/2020 11/13/2023
Spill Contain Device Single Wall Spill Bucket 8/13/2025 8/13/2028
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms