Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2002997
Status: Inactive
Facility Name: XPO, Inc.
Address: 450 S. Second St. Elgin, IL 60123
County: Kane
Property Parcel: 06-21-278-004
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y003945
Green Tag Issue Date: 3/31/2023
Green Tag Expire Date: 12/31/2025
MFD Type: N/A

Owner Details

Owner Name: RLIF Central, LLC
Owner Address: 201 West Street Annapolis, MD 21401
Owner Status: Current Owner
Purchase Date: 12/19/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/11/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041469 RLIF Central, LLC Current Owner 12/19/2019
U0029881 Conway Transportation Inc Former Owner 9/29/2000
U0038082 XPO Logistics Freight, Inc. Former Owner
U0012150 Preston Corporation Former Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-0987 4/20/1999 Removal Log 01061-1999REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1999
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 12/19/1998 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1999
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 12/19/1998 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/1999
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 12/22/1997 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/4/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 10/17/2000 Red Tag Issue Date: 11/21/2025
Last Used Date: 1/28/2025 Fee Due: $0.00
Product Date: 10/28/2000

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/27/2024 9/27/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 9/27/2024 9/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/27/2024 9/27/2025
Overfill Prev Device Overfill Alarm 9/27/2024 9/27/2027
Overfill Prev Device Overfill Drop Tube Valve 9/27/2024 9/27/2027
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/6/2022 5/6/2025
Leak Detect - Piping Sump Sensor 5/6/2022 5/6/2025
Spill Contain Device Single Wall Spill Bucket 9/27/2024 9/27/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/27/2024

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found