Facility Details
| Facility Number: |
2002900 |
| Status: |
Closed |
| Facility Name: |
Harry W. Kuhn, Inc. |
| Address: |
28 West 651 North Avenue Rt. 64 West Chicago, IL 60185 |
| County: |
Du Page |
| Property Parcel: |
|
| Facility Type: |
Industrial / Manufacturing |
| Owner Type: |
Private |
| Green Tag Decal: |
F000707 |
| Green Tag Issue Date: |
6/17/2004 |
| Green Tag Expiration Date: |
12/31/2007 |
Owner Details
| Owner Name: |
Family Limited Partnership 1 |
| Owner Address: |
207 Illinois Avenue St. Charles, IL 60174 |
| Owner Status: |
Current Owner |
| Purchase Date: |
1/1/1998 |
| Type of Financial Responsibility: |
Designated Savings Account |
| Financial Responsibility Reporting Due Date: |
7/2/2013 |
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0036569 |
Family Limited Partnership 1 |
Current Owner |
1/1/1998 |
| U0006528 |
Harry W. Kuhn, Inc. |
Former Owner |
1/1/1980 |
Notice of Violatlions (Current)
No Notice of Violations Found
NOVs Outstanding With Complied/Closed Deficiencies
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 12-0691 |
8/1/2012 |
Removal Log |
00688-2012REM |
| 12-0691 |
8/2/2012 |
Removal Log |
00688-2012REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 12-0691 |
Eligible |
7/13/2012
|
8/29/2012
|
$5,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/2/2012 |
|
OSFM
First Notify Date: |
3/10/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1981 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
|
|
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
|
|
|
Leak Detect - Piping
|
European with No Test Req Suction |
N/A |
N/A |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
|
|
|
Piping
|
Steel Single Wall Piping |
N/A |
N/A |
|
Spill Contain Device
|
Single Wall Spill Bucket |
|
|
|
Tank
|
Steel Single Wall |
N/A |
N/A |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/2/2012 |
|
OSFM
First Notify Date: |
3/10/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1981 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
|
|
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
|
|
|
Leak Detect - Piping
|
European with No Test Req Suction |
N/A |
N/A |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
|
|
|
Piping
|
Steel Single Wall Piping |
N/A |
N/A |
|
Spill Contain Device
|
Single Wall Spill Bucket |
|
|
|
Tank
|
Steel Single Wall |
N/A |
N/A |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 3
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/1/2012 |
|
OSFM
First Notify Date: |
3/10/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1981 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
|
|
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
|
|
|
Leak Detect - Piping
|
European with No Test Req Suction |
N/A |
N/A |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
|
|
|
Piping
|
Steel Single Wall Piping |
N/A |
N/A |
|
Spill Contain Device
|
Single Wall Spill Bucket |
|
|
|
Tank
|
Steel Single Wall |
N/A |
N/A |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 4
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/1/2012 |
|
OSFM
First Notify Date: |
3/10/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1981 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
|
|
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
|
|
|
Leak Detect - Piping
|
European with No Test Req Suction |
N/A |
N/A |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
|
|
|
Piping
|
Steel Single Wall Piping |
N/A |
N/A |
|
Spill Contain Device
|
Single Wall Spill Bucket |
|
|
|
Tank
|
Steel Single Wall |
N/A |
N/A |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 5
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/1/2012 |
|
OSFM
First Notify Date: |
3/10/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1981 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
|
|
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
|
|
|
Leak Detect - Piping
|
European with No Test Req Suction |
N/A |
N/A |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
|
|
|
Piping
|
Steel Single Wall Piping |
N/A |
N/A |
|
Spill Contain Device
|
Single Wall Spill Bucket |
|
|
|
Tank
|
Steel Single Wall |
N/A |
N/A |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 6
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/2/2012 |
|
OSFM
First Notify Date: |
3/20/1986 |
|
Abandoned Material: |
|
| Current Age: |
|
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Tank Number 7
| Capacity: |
550 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/2/2012 |
|
OSFM
First Notify Date: |
3/20/1986 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1980 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/1/2005 |
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1980 |
|
|
|
Equipment
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Leak Detect - Piping
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
|
Leak Detect - Tank
|
Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite |
|
|
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found