Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2002726
Status: Active
Facility Name: Nancy's Citgo
Address: 8050 W. Ogden Lyons, IL 60534
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000272
Green Tag Issue Date: 7/9/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: S.A. Property Management, Inc.
Owner Address: 8050 Ogden Ave. Lyons, IL 60534
Owner Status: Current Owner
Purchase Date: 3/28/2016
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 7/26/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/9/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038387 S.A. Property Management, Inc. Current Owner 3/28/2016
U0004397 Ray & Nancy Durson d/b/a Nancy's Gas & Food Mart, Inc., Former Owner 1/1/1990
U0024018 Leuck Matt J Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020253228 (Pending)    Issue Date: 12/9/2025    Expiration Date: 2/7/2026    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly - https://webapps.sfm.illinois.gov/USTPortal/Forms/Financial Responsibility
6 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - DUE BY 12-19-25
6 Triennial spill prevention equipment testing not completed. - DUEBY 12-19-25
5, 6 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - DISPENSER SUMPS AND STP CONTAINMENT SUMPS ARE DUE BY 12-19-25

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-0462 Eligible 8/11/2004 9/1/2004 $10,000
90-3267 Eligible 12/18/2014 2/11/2015 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/11/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 7/21/2004
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/11/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 7/21/2004
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/11/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 7/21/2004
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/7/1989 Abandoned Material: Inert material mixed with portland cement
Current Age: 49 Abandoned Date: 9/8/1998
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 7/26/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/26/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/17/2025 3/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 3/17/2025 3/17/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/17/2025 3/17/2026
Overfill Prev Device Overfill Drop Tube Valve 6/5/2024 6/5/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 12/19/2022 12/19/2025
Leak Detect - Piping Sump Sensor 3/17/2025 3/17/2026
Spill Contain Device Double Wall Spill Bucket 6/5/2024 6/5/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/11/2019



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 7/26/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/26/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/17/2025 3/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 3/17/2025 3/17/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/17/2025 3/17/2026
Overfill Prev Device Overfill Drop Tube Valve 12/19/2022 12/19/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 12/19/2022 12/19/2025
Leak Detect - Piping Sump Sensor 3/17/2025 3/17/2026
Spill Contain Device Single Wall Spill Bucket 12/19/2022 12/19/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/11/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/19/2022 12/19/2025
Leak Detect - Piping Stand Alone Sump Sensor 3/17/2025 3/17/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/19/2022 12/19/2025
Leak Detect - Piping Stand Alone Sump Sensor 3/17/2025 3/17/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/19/2022 12/19/2025
Leak Detect - Piping Stand Alone Sump Sensor 3/17/2025 3/17/2026

MFD Motorfuel Dispensing Forms

No Forms Found