Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2001699
Status: Active
Facility Name: Evergreen Park Citgo
Address: 2801 W. 87th Street
Evergreen Park, IL 60805
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002467
Green Tag Issue Date: 11/6/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Bview Corporation
Owner Address: 2801 W. 87th Street
Evergreen Park, IL 60805
Owner Status: Current Owner
Purchase Date: 8/29/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/14/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/6/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037374 Bview Corporation Current Owner 8/29/2013
U0031909 A & R Marketers, Inc. Former Owner 9/24/2002
U0030464 Emanuel, Joseph Former Owner 11/1/2001
U0022096 James P Kotsiviras Former Owner 1/4/1993
U0009677 Marek Thomas Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250558 (Pending)    Issue Date: 3/5/2025    Expiration Date: 5/4/2025    View NOV Form

Tanks Violation
6 Miscellaneous - Adequate collision protection to protect against physical damage shall be provided for vent piping. 175.440 a)8)
6 Miscellaneous - Equipment in Disrepair - All equipment and other items shall be maintained in accordance with 41 Ill. Adm. Code 174 through 176 and manufacturer's instructions and otherwise shall be kept in good operating condition at all times. Reference 176.410
7 Miscellaneous - Adequate collision protection to protect against physical damage shall be provided for vent piping. 175.440 a)8)
7 Miscellaneous - Equipment in Disrepair - All equipment and other items shall be maintained in accordance with 41 Ill. Adm. Code 174 through 176 and manufacturer's instructions and otherwise shall be kept in good operating condition at all times. Reference 176.410
8 Miscellaneous - Adequate collision protection to protect against physical damage shall be provided for vent piping. 175.440 a)8)
6, 7, 8 Piping interstitial must be open in all sumps - Product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. 175.420 b) (STPs and Dispensers)
6, 7, 8 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020250559 (Pending)    Issue Date: 3/5/2025    Expiration Date: 5/4/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers. Reference 175.210 h)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
16-0962 1/5/2017 Removal Log 01494-2016REM
99-1550 6/25/1999 Removal Log 01982-1999REM
99-1558 6/25/1999 Removal Log 01982-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20160962 Eligible 2/23/2017 2/23/2017 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/5/2017
OSFM First Notify Date: 2/28/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 7/1/2014 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/26/2015 6/26/2018
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/8/2014 7/8/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2015 6/30/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/5/2017
OSFM First Notify Date: 2/28/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/26/2015 6/26/2018
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/8/2014 7/8/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2015 6/30/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/5/2017
OSFM First Notify Date: 2/28/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/26/2015 6/26/2018
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/8/2014 7/8/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2015 6/30/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/1999
OSFM First Notify Date: 11/26/1991 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 12/21/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 500 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 11/26/1991 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2024 10/1/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/1/2024 10/1/2025
Overfill Prev Device Overfill Drop Tube Valve 10/1/2024 10/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025
Spill Contain Device Double Wall Spill Bucket 9/11/2023 9/11/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/1/2024



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2024 10/1/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/1/2024 10/1/2025
Overfill Prev Device Overfill Drop Tube Valve 10/1/2024 10/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025
Spill Contain Device Double Wall Spill Bucket 9/11/2023 9/11/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/1/2024



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2024 10/1/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/1/2024 10/1/2025
Overfill Prev Device Overfill Drop Tube Valve 10/1/2024 10/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025
Spill Contain Device Double Wall Spill Bucket 9/11/2023 9/11/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/1/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/11/2023 9/11/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/1/2024 10/1/2025

MFD Motorfuel Dispensing Forms

No Forms Found