Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2001553
Status: Active
Facility Name: Valvoline Instant Oil Change
Address: 3808 S Western Ave
Chicago, IL 60609
County: Cook
Property Parcel: 16-36-428-011-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Z002288
Green Tag Issue Date: 7/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Ivy Lane Corporation
Owner Address: 1001 Grand Avenue
West Des Moines, IA 50265
Owner Status: Current Owner
Purchase Date: 1/7/2022
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 5/12/2026

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040526 Ivy Lane Corporation Current Owner 1/7/2022
U0011282 Oil Express National, Inc. Former Owner
U0011283 Oil Express Natl Inc - DO NOT USE THIS OWNER ID Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: New Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/2/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 2/2/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 6/14/2024 6/14/2027
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 6/14/2024 6/14/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries 6/14/2024 6/14/2025
Overfill Prev Device Overfill Drop Tube Valve 6/17/2022 6/17/2025
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/17/2022 6/17/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 6/14/2024



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/2/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 2/2/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 6/14/2024 6/14/2027
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 6/14/2024 6/14/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries 6/14/2024 6/14/2025
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/17/2022 6/17/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 6/14/2024

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found