Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2001497
Status: Active
Facility Name: Lockport Township High District 205
Address: 1332 E. Division
Lockport, IL 60441
County: Will
Property Parcel:
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: Z004201
Green Tag Issue Date: 8/27/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Lockport Township High School Dist. 205
Owner Address: 1323 East 7th Street
Lockport, IL 60441
Owner Status: Current Owner
Purchase Date: 7/1/1978
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/27/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009295 Lockport Township High School Dist. 205 Current Owner 7/1/1978

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 1 8/12/2024 8/12/2025
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/12/2020
Tank Steel Single Wall Precision Test (Tank) Pass 6/12/2020



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 1 8/12/2024 8/12/2025
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/12/2020
Tank Steel Single Wall Precision Test (Tank) Pass 6/12/2020



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/12/2024 8/12/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 1 8/12/2024 8/12/2025
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/12/2020
Tank Steel Single Wall Precision Test (Tank) Pass 6/12/2020

Dispenser Information



Name\ID 1 diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 1 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2 diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found