Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000890
Status: Active
Facility Name: TNC Gas Company, Inc.
Address: 17002 Torrence Ave.
Lansing, IL 60438
County: Cook
Property Parcel: 29-25-201-008-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002609
Green Tag Issue Date: 5/17/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: TNC Gas Company, Inc.
Owner Address: 17002 Torrence Ave.
Lansing, IL 60438
Owner Status: Current Owner
Purchase Date: 11/9/2006
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/22/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/11/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033909 TNC Gas Company, Inc. Current Owner 11/9/2006
U0023834 BP Amoco Former Owner 3/31/1995
U0027493 Amoco Oil Company Former Owner 1/1/1987
U0000552 BP Products North America, Inc. Former Owner 1/1/1987

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00524-2025UPG Upgrade Approved / Issued 5/1/2025 5/1/2025 11/4/2025 Documents

Notice of Violations (Current)

NOV Number: E0020251047 (Pending)    Issue Date: 4/17/2025    Expiration Date: 6/16/2025    View NOV Form

Tanks Violation
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Minimum signage is not up to code. Reference 175.210 o)
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers. Reference 175.210 h)

NOV Number: E0020251048 (Pending)    Issue Date: 4/17/2025    Expiration Date: 6/16/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Only one emergency stop was tested. There are 2.
2 Install or replace lockable fill pipe caps. - Missing gasket on Fill snap cap. Repair/Replace
1 Line leak detection equipment in alarm or failed test, must repair or replace. - Failed testing 1/6/2025.
1 Line leak detection equipment in alarm or failed test, must repair or replace. - W1 and W2 Plld is in alarm.
2 Line leak detection equipment in alarm or failed test, must repair or replace. - Failed testing 1/6/2025.
2 Line leak detection equipment in alarm or failed test, must repair or replace. - W1 and W2 Plld is in alarm.
3 Line leak detection equipment in alarm or failed test, must repair or replace. - Failed testing 1/6/2025.
3 Line leak detection equipment in alarm or failed test, must repair or replace. - W1 and W2 Plld is in alarm.
Facility Miscellaneous - Each emergency stop shall be identified by an approved sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. Reference 175.210 d)3) (Both inside and Outside)
1, 2 Miscellaneous - Verify double poppet shear valves.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
1, 2, 3 Monthly impressed current log not available or maintained. - Form can be found at https://sfm.illinois.gov to download and complete.
1, 2, 3 Monthly impressed current system log not available or maintained. - Form can be found at https://sfm.illinois.gov to download and complete.
2 Open electrical conduit or junction boxes. - Center Regular Atg. Conduit is broke. Repair/replace.
1, 2, 3 Shear valve(s) not properly mounted and/or not at proper height. - Shear is to low.
1, 2 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3 Tank monitor does not appear to function properly and requires maintenance. - Green light is not working.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: 5/1/2025 Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/2/2024 1/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2025 1/2/2026
Overfill Prev Device Overfill Drop Tube Valve 1/2/2024 1/2/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/2/2024 1/2/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 1/2/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/2/2025 5/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2025 1/2/2026
Overfill Prev Device Overfill Drop Tube Valve 1/2/2024 1/2/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/2/2024 1/2/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 1/2/2025



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/2/2025 1/2/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/2/2025 5/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2025 1/2/2026
Overfill Prev Device Overfill Drop Tube Valve 1/2/2024 1/2/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/2/2024 1/2/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 1/2/2025



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/2004
OSFM First Notify Date: 11/16/1987 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 7/1/2004 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found