Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2000768
Status:
Active
Facility Name:
7-Eleven #30153
Address:
51 South Randall Road
St. Charles, IL 60174
County:
Kane
Property Parcel:
09-32-200-034
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z001433
Green Tag Issue Date:
5/1/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
7-Eleven, Inc.
Owner Address:
3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
12/13/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
5/1/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0014207
7-Eleven, Inc.
Current Owner
U0014209
Southland Corporation
Former Owner
1/1/1985
U0023040
7-Eleven, Inc./DO NOT USE #
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
04-0468
4/7/2004
Removal Log
04231-2004REM
96-1715
9/17/1996
Removal Log
1279-96
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
93-1640
Eligible
4/11/1995
4/24/1995
$10,000
04-0468
Eligible
8/27/2004
9/17/2004
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/17/1996
OSFM
First Notify Date:
1/30/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/17/1996
OSFM
First Notify Date:
1/30/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/17/1996
OSFM
First Notify Date:
1/30/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
15000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/7/2004
OSFM
First Notify Date:
4/22/1997
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
11/1/1996
Red Tag Issue Date:
Last Used Date:
4/5/2004
Fee Due:
$0.00
Product Date:
11/1/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/7/2004
OSFM
First Notify Date:
4/22/1997
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
11/1/1996
Red Tag Issue Date:
Last Used Date:
4/5/2004
Fee Due:
$0.00
Product Date:
11/1/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/7/2004
OSFM
First Notify Date:
4/22/1997
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
11/1/1996
Red Tag Issue Date:
Last Used Date:
4/5/2004
Fee Due:
$0.00
Product Date:
11/1/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
15000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/5/2004
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
11/21/2003
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/21/2003
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Polyethylene Chase
N/A
N/A
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/1/2024
8/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/29/2024
7/29/2027
Piping
Flexible Double Wall OPW Flexworks
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Spill Contain Device
Double Wall Spill Bucket
7/29/2024
7/29/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
2/8/2024
Piping
Flexible Double Wall OPW Flexworks
Precision Test (Piping)
Pass
8/1/2024
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
7/29/2024
Tank Number 8
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/5/2004
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
11/21/2003
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/21/2003
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Polyethylene Chase
N/A
N/A
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/1/2024
8/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
8/1/2024
8/1/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/29/2024
7/29/2027
Piping
Flexible Double Wall OPW Flexworks
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Spill Contain Device
Double Wall Spill Bucket
7/29/2024
7/29/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall OPW Flexworks
Precision Test (Piping)
Pass
8/1/2024
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
7/29/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/15/2024
7/15/2027
Leak Detect - Piping
Sump Sensor
8/1/2024
8/1/2025
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2000768
7-Eleven #30153
St. Charles
06/03/2024
Letter
Form