Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000765
Status: Active
Facility Name: Larkin Exxon, LLC
Address: 1032 Larkin Ave. Elgin, IL 60123
County: Kane
Property Parcel: 06-15-280-022
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001396
Green Tag Issue Date: 3/1/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Larkin Exxon, LLC
Owner Address: 1032 Larkin Ave. Elgin, IL 60123
Owner Status: Current Owner
Purchase Date: 9/30/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041830 Larkin Exxon, LLC Current Owner 9/30/2020
U0035735 True North Energy, LLC Former Owner 3/8/2010
U0028798 Equilon Enterprises, LLC Former Owner 12/1/1998
U0038978 KR 2005, Inc. Former Owner
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0023652 Gas & Grub Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261401 (Pending)    Issue Date: 5/28/2026    Expiration Date: 7/27/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain most current 2 years on site with other annual testing documentation. ONLY 2 0F 3 ESTOPS TESTED IN 2024 AND 2025.
Facility Financial responsibility must be reported yearly - Financial Responsibility shall be declared annually, and must be maintained until the tanks are removed or properly abandoned in place by a licensed UST decommissioning contractor. The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility. ENSURE THAT THE NEW OWNERSHIP CHANGE IS PROCESSED, THEN SUBMIT THE FINANCIAL RESPONSIBILITY.
Facility Submit Notification Form for Ownership Change - Per 41 Ill. Adm. Code 176.440(g), a change in ownership information must be reported on an electronic Notification for Underground Storage Tank form, within 30 days of the change. This facility had ownership change on 9/30/2020. The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm .

NOV Number: E0020261402 (Pending)    Issue Date: 5/28/2026    Expiration Date: 7/27/2026    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
05-1287 Eligible 10/21/2005 12/6/2005 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/28/2016
OSFM First Notify Date: 1/24/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/23/1981 Red Tag Issue Date:
Last Used Date: 6/1/2011 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/19/2011 5/19/2012
Corrosion Prot - Tank Lining Materials Internal 9/11/2007 9/11/2012
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2013 4/3/2014
Leak Detect - Piping Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Piping Stand Alone Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 2/18/2011



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/28/2016
OSFM First Notify Date: 1/24/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/23/1981 Red Tag Issue Date:
Last Used Date: 6/1/2011 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/19/2011 5/19/2012
Corrosion Prot - Tank Lining Materials Internal 9/11/2007 9/11/2012
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2013 4/3/2014
Leak Detect - Piping Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Piping Stand Alone Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 2/18/2011



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/28/2016
OSFM First Notify Date: 1/24/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 8/9/2013 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2013 4/3/2014
Leak Detect - Piping Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Piping Stand Alone Sump Sensor 2/18/2011 2/18/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 2/18/2011



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 12/14/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/23/2026 6/23/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/23/2026 6/23/2027
Overfill Prev Device Overfill Drop Tube Valve 6/23/2026 6/23/2029
Piping Flexible Double Wall OmegaFlex DoubleTrac Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2029
Piping Ball Valves Not applicable Not applicable
Piping Shear Valves Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 6/23/2026 6/23/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 6/23/2026



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 12/14/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/23/2026 6/23/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/23/2026 6/23/2027
Overfill Prev Device Overfill Drop Tube Valve 6/23/2026 6/23/2029
Piping Flexible Double Wall OmegaFlex DoubleTrac Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2029
Piping Ball Valves Not applicable Not applicable
Piping Shear Valves Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 6/23/2026 6/23/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 6/23/2026



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 12/14/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/23/2026 6/23/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/23/2026 6/23/2027
Overfill Prev Device Overfill Drop Tube Valve 6/23/2026 6/23/2029
Piping Flexible Double Wall OmegaFlex DoubleTrac Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2029
Piping Ball Valves Not applicable Not applicable
Piping Shear Valves Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 6/23/2026 6/23/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 6/23/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/23/2026 6/23/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/23/2026 6/23/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2000765 Larkin Exxon, LLC Elgin 08/15/2018 Letter Form