Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000271
Status: Active
Facility Name: Neiman Bros. Co., Inc.
Address: 3322 W Newport Ave Chicago, IL 60618
County: Cook
Property Parcel: 13-23-402-036-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: AA02259
Green Tag Issue Date: 5/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: Neiman Bros. Co., Inc.
Owner Address: 3322 W. Newport Ave. Chicago, IL 60618
Owner Status: Current Owner
Purchase Date: 4/12/1978
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/30/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041775 Neiman Bros. Co., Inc. Current Owner 4/12/1978
U0010901 Neiman Brothers, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00352-2026INS Install Approved / Issued 3/30/2026 4/1/2026 10/1/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 9000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1994
OSFM First Notify Date: 1/7/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 1/1/1985
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1984 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/14/2001 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/24/2022 3/24/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 7/10/2025 7/10/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2024 5/30/2027
Piping Fiberglass Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/30/2024 5/30/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 3/25/2022



Tank Number 3

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Not Installed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2000271 Neiman Bros. Co., Inc. Chicago 03/30/2026 Letter Form