Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000271
Status: Installed/Not in Use
Facility Name: Neiman Bros. Co., Inc.
Address: 3322 W Newport Ave Chicago, IL 60618
County: Cook
Property Parcel: 13-23-402-036-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: AA02259
Green Tag Issue Date: 5/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: Neiman Bros. Co., Inc.
Owner Address: 3322 W. Newport Ave. Chicago, IL 60618
Owner Status: Current Owner
Purchase Date: 4/12/1978
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/30/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041775 Neiman Bros. Co., Inc. Current Owner 4/12/1978
U0010901 Neiman Brothers, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00649-2026REM Removal Approved / Issued 6/10/2026 6/10/2026 12/10/2026 Documents
00352-2026INS Install Approved / Issued 3/30/2026 4/1/2026 10/1/2026 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2026-0470 7/13/2026 Removal Log 00649-2026REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 9000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1994
OSFM First Notify Date: 1/7/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 1/1/1985
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1984 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/13/2026
OSFM First Notify Date: 8/14/2001 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1992

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 3/24/2022 3/24/2027
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 7/10/2025 7/10/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2024 5/30/2027
Piping Fiberglass Chase Not applicable Not applicable
Piping Steel Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 5/30/2024 5/30/2027
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 3/25/2022



Tank Number 3

Capacity: 3000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/28/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/15/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/17/2026

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Overfill Prev Device Overfill Drop Tube Valve 7/24/2026 7/24/2029
Spill Contain Device Double Wall Spill Bucket 7/22/2026 7/22/2029
Tank Composite Double Wall Zorn Elutron Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/22/2026 7/22/2029

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2000271 Neiman Bros. Co., Inc. Chicago 03/30/2026 Letter Form