Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 1047449
Status: Active
Facility Name: QuiK Trip #7203
Address: 1320 May Rd. Peru, IL 61354
County: LaSalle
Property Parcel: 17-04-107-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003400
Green Tag Issue Date: 6/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: QuikTrip Corporation
Owner Address: 4705 South 129th East Ave. Tulsa, OK 74134
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/11/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/5/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034559 QuikTrip Corporation, Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251780 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
3, 6, 7, 9, 10 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Document that emergency shut-off (shear valves) are in proper working order
1, 2, 3, 4, 5, 7 Line interstitial sensor functional test not accomplished (Required annually). - Tank top sumps as indicated and dispensers 1/2, 3/4, 5/6, 7/8, 9/10, 11/12, 15/16, 17/18 do not have current test results for 2025.
7, 8, 9, 10 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed. Sensors are not in the lowest point of the UDC at diesel pumps 4, 5,6 and 7. All have a notable amount of liquid present.
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copies of current testing certificates for operator training - AB Certificate is missing for the individual conducting the 30 day walkthrough inspection. Last documented inspection was April 2025.
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3, 4, 5 Tank interstitial sensor functional test not accomplished (Required annually).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 20000 Gasoline - Regular Currently in use Federal $0.00
2 20000 Gasoline - Regular Currently in use Federal $0.00
3 20000 Gasoline - Regular Currently in use Federal $0.00
4 20000 Gasoline - Non Ethanol Currently in use Federal $0.00
5 20000 Gasoline - Premium Currently in use Federal $0.00
6 18000 B-99 Currently in use Federal $0.00
7 30000 Diesel Fuel Currently in use Federal $0.00
8 30000 Diesel Fuel Currently in use Federal $0.00
9 30000 Diesel Fuel Currently in use Federal $0.00
10 30000 Diesel Fuel Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
1D/2D Active
2D/3D Active
3/4 Active
3D/4D Active
4D/5D Active
5/6 Active
5D/6D Active
6D/7D Active
7/8 Active
7D/8D Active
9/10 Active
11/12 Active
13/14 Active
15/16 Active
17/18 Active

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1047449 QuiK Trip #7203 Peru 05/22/2023 Letter Form