Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1047333
Status: Active
Facility Name: HP DJ Operating LLC
Address: 13785 IL Route 72 Davis Junction, IL 61020
County: Ogle
Property Parcel: 11-23-200-023
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001835
Green Tag Issue Date: 5/10/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: HP DJ Real Estate, LLC
Owner Address: P.O. Box 67 Rochelle, IL 61068
Owner Status: Current Owner
Purchase Date: 2/11/2022
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/10/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041704 HP DJ Real Estate, LLC Current Owner 2/11/2022
U0039519 HP Rochelle Real Estate, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260086 (Pending)    Issue Date: 1/13/2026    Expiration Date: 3/14/2026    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly - Financial Responsibility under the new owner name must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
Facility Submit Notification Form For Ownership Change

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2022 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 2/2/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging 8/12/2025 8/12/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 8/20/2025 8/20/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 5/23/2022 5/23/2023
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026
Spill Contain Device Single Wall Spill Bucket 8/20/2025 8/20/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 5/23/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/23/2022



Tank Number 2

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2022 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 2/2/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging 8/12/2025 8/12/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 8/20/2025 8/20/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 5/23/2022 5/23/2023
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026
Spill Contain Device Single Wall Spill Bucket 8/20/2025 8/20/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 5/23/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/23/2022



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2022 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 2/2/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging 8/12/2025 8/12/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 8/12/2025 8/12/2028
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 8/20/2025 8/20/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 5/23/2022 5/23/2023
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026
Spill Contain Device Single Wall Spill Bucket 8/20/2025 8/20/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 5/23/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/23/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 11S/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/20/2025 8/20/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1047333 HP DJ Operating LLC Davis Junction 05/18/2022 Letter Form