Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1045806
Status: Active
Facility Name: Pearl City Eggs
Address: 968 S Kent Rd Pearl City, IL 61062
County: Stephenson
Property Parcel: 01-16-03-200-002
Facility Type: Farm
Owner Type: Private
Green Tag Decal: AA02103
Green Tag Issue Date: 8/19/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Pearl Valley Eggs
Owner Address: 968 S Kent Rd Pearl City, IL 61062
Owner Status: Current Owner
Purchase Date: 12/19/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/30/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/19/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037650 Pearl Valley Eggs Current Owner 12/19/2014

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/23/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/19/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 3/20/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 2/24/2025 2/24/2028
Piping Flexible Double Wall OPW Pisces N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 2/9/2023 2/9/2024
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Single Wall Spill Bucket 2/24/2025 2/24/2028
Tank Fiberglass Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/23/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/19/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 2/24/2025 2/24/2028
Piping Flexible Double Wall OPW Pisces N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 2/9/2023 2/9/2024
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Single Wall Spill Bucket 2/24/2025 2/24/2028
Tank Fiberglass Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/23/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/19/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 2/24/2025 2/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/24/2025 2/24/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 2/24/2025 2/24/2028
Piping Flexible Double Wall OPW Pisces N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 2/9/2023 2/9/2024
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026
Spill Contain Device Single Wall Spill Bucket 2/24/2025 2/24/2028
Tank Fiberglass Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor 2/24/2025 2/24/2026

MFD Motorfuel Dispensing Forms