Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1043644
Status: Active
Facility Name: Sullivan's Foods
Address: 125 Backbone Road Princeton, IL 61356
County: Bureau
Property Parcel: 16-04-300-048
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Y002245
Green Tag Issue Date: 4/25/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: J B Sullivan, LLC
Owner Address: 425 First Street Savanna, IL 61074
Owner Status: Current Owner
Purchase Date: 6/20/2023
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/25/2023 12/31/2025
Unattended Self Service 4/25/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041114 J B Sullivan, LLC Current Owner 6/20/2023
U0029040 JB Sullivan, Inc. Former Owner 6/20/2023
U0030845 Sullivan's Food Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252002 (Pending)    Issue Date: 8/6/2025    Expiration Date: 10/5/2025    View NOV Form

Tanks Violations
Facility A/B operator retraining required as a result of issuance of the Notice of Violation - Information on operator training can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/operator-training.html
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Obtain from contractor performing the annual testing. Contractor search: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety.html
1, 2, 3 Document that emergency shut-off (shear valves) are in proper working order - Obtain from contractor performing the annual testing. Contractor search: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety.html
Facility Emergency contact information for A/B & C Operators not posted at unmanned facility
Facility Facility Operation and Maintenance Plan not updated to new requirements. - Form can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/operator-training.html
Facility Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
Facility Missing copies of 30 day Walkthrough Inspection Report. - Form can be found at :https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/operator-training.html
Facility Missing copies of Annual Walkthrough Inspection Report. - Obtain from contractor performing the annual testing. Contractor search: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety.html
Facility Missing copies of current testing certificates for operator training
Facility Missing copy of emergency instructions or emergency procedures plan - Form can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing list of designated Class A/B & C Operators - Form can be found at :https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/operator-training.html
1, 2, 3 Monthly line interstitial sensor records not available.
1, 2, 3 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
1, 2, 3 Required monthly tank interstitial sensor records not available. - Site requires IM for tank leak detection. Sensors are not present on the ATG printout. Either add to the ATG or remove as a Tank Leak detection method via a permit application.
1, 2, 3 Required monthly tank leak test records not available.
2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
Facility Submit Notification Form For Ownership Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of an ownership change.
1, 2, 3 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - STP sumps

NOV Number: E0020252047 (Pending)    Issue Date: 8/6/2025    Expiration Date: 10/5/2025    View NOV Form

Tanks Violations
Facility Annual Fire Detection Test has not been performed

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/4/2007 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 6/5/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/24/2025 6/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2025 6/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2025 6/24/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 7/22/2022 6/24/2025
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 7/22/2022 7/22/2025
Leak Detect - Piping Sump Sensor 6/24/2025 6/24/2026
Spill Contain Device Single Wall Spill Bucket 6/24/2025 6/24/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/18/2019



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/4/2007 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 6/5/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/24/2025 6/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2025 6/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2025 6/24/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 7/22/2022 6/24/2025
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 7/22/2022 7/22/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 7/22/2022 7/22/2023
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2025 6/24/2026
Spill Contain Device Single Wall Spill Bucket 6/24/2025 6/24/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/18/2019



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/4/2007 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 6/5/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/24/2025 6/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2025 6/24/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2025 6/24/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 7/22/2022 6/24/2025
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 7/22/2022 7/22/2025
Leak Detect - Piping Sump Sensor 6/24/2025 6/24/2026
Spill Contain Device Single Wall Spill Bucket 6/24/2025 6/24/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/18/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms