Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1043149
Status: Active
Facility Name: Stockton Travel Center
Address: 600 East North Avenue, Highway 20
Stockton, IL 61085
County: Jo Daviess
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000871
Green Tag Issue Date: 5/23/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Saunders Oil Company, Inc.
Owner Address: 115 Gratiot Street
Warren, IL 61087
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/19/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/23/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013448 Saunders Oil Company, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250818 (Pending)    Issue Date: 3/27/2025    Expiration Date: 5/26/2025    View NOV Form

Tanks Violation
Facility Financial responsibility must be reported yearly - Financial Responsibility shall be declared annually; declaration form can be found at www.sfm.illinois.gov (in Search window, type UST Forms, Click Enter; click UST Applications and Forms; click on Financial Responsibility Report). Complete form online and submit electronically.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/29/2024 4/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 4/29/2024 4/29/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/29/2024 4/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 4/29/2024 4/29/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/29/2024 4/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 4/29/2024 4/29/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/6/2024 5/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 5/6/2024 5/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/6/2024 5/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 5/6/2024 5/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: 100% Soy Oil (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Alarm
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/6/2024 5/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 5/6/2024 5/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/6/2024 5/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 5/6/2024 5/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Racing Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/14/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/6/2024 5/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/29/2024 4/29/2025
Overfill Prev Device Overfill Alarm 5/6/2024 5/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025
Spill Contain Device Single Wall Spill Bucket 5/6/2024 5/6/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 4/5/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2024 5/6/2027
Leak Detect - Piping Sump Sensor 4/29/2024 4/29/2025

MFD Motorfuel Dispensing Forms