Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1038981
Status: Active
Facility Name: Flying J Travel Plaza #644
Address: 343 Civic Road La Salle, IL 61301
County: LaSalle
Property Parcel: 11-34-319-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001897
Green Tag Issue Date: 10/3/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Pilot Travel Centers, LLC
Owner Address: 5508 Lonas Rd. Knoxville, TN 37909
Owner Status: Current Owner
Purchase Date: 7/1/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/18/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/3/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011913 Pilot Travel Centers, LLC Current Owner 7/1/2010
U0028776 Flying J, Inc. Former Owner 8/6/1999

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01220-2025UPG Upgrade Approved / Issued 9/18/2025 9/18/2025 3/18/2026 Documents
01047-2025UPG Upgrade Approved / Issued 8/11/2025 8/11/2025 2/11/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020252540 (Pending)    Issue Date: 9/25/2025    Expiration Date: 11/24/2025    View NOV Form

Tanks Violations
4, 5 Line leak detection equipment in alarm or failed test, must repair or replace. - MLLD failed on both tanks.
1 Spill prevention equipment failed triennial testing. Must be repaired or replaced.
4 Submit Notification Form for Product Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm
4 The Blended Fuel Compatibility Form for products greater than E10 and B20 has not been submitted as required. - Owners and operators are required to submit a Blended Fuel Compatibility Form 30 days prior to switching to a blended fuel product.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
15-0544 Eligible 1/22/2016 3/2/2016 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/6/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/10/2025 9/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/23/2025 9/23/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/10/2025 9/10/2026
Overfill Prev Device Overfill Drop Tube Valve 11/30/2023 11/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Piping Single Wall Transition Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Piping Single Wall Transition Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Spill Contain Device Double Wall Spill Bucket 11/11/2025 11/11/2028
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/10/2025
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/10/2025
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 3/12/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 11/16/2009



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/6/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/10/2025 9/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/10/2025 9/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/10/2025 9/10/2026
Overfill Prev Device Overfill Drop Tube Valve 11/1/2023 11/1/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Spill Contain Device Double Wall Spill Bucket 6/11/2025 6/11/2028
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/10/2025
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/10/2025
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 3/12/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 11/16/2009



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/6/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/10/2025 9/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/10/2025 9/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/10/2025 9/10/2026
Overfill Prev Device Overfill Drop Tube Valve 11/1/2023 11/1/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Spill Contain Device Double Wall Spill Bucket 4/29/2025 4/29/2028
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/10/2025
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/10/2025
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 3/12/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 11/16/2009



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/6/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/10/2025 9/23/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/10/2025 9/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/10/2025 9/10/2026
Overfill Prev Device Overfill Drop Tube Valve 9/9/2025 9/9/2028
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 10/10/2024 10/10/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/10/2025 9/10/2026
Spill Contain Device Single Wall Spill Bucket 4/29/2025 4/29/2028
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/23/2025
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 3/12/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 10/3/2009



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/6/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2023 4/14/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/2/2025 10/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/10/2025 9/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/10/2025 9/10/2026
Overfill Prev Device Overfill Drop Tube Valve 1/5/2024 1/5/2027
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/8/2025 4/8/2028
Leak Detect - Piping Sump Sensor 9/10/2025 9/10/2026
Spill Contain Device Double Wall Spill Bucket 4/29/2025 4/29/2028
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 9/10/2025
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 3/12/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 10/3/2009

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 14/15

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 17 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 17 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 18 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 18 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 19 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 19 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 20 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 21 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 21 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 22 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 22 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 23 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 23 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 24 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 24 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 25 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 25 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 26 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 26 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 27 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 27 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 28 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 28 SAT

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/8/2025 4/8/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1038981 Flying J Travel Plaza #644 La Salle 10/22/2025 Letter Form