Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1029430
Status: Active
Facility Name: Brake Time
Address: 125 S. Bloomington Road
Grand Ridge, IL 61325
County: LaSalle
Property Parcel: 27-24-100-029
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001814
Green Tag Issue Date: 1/8/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Brake Time IL Properties, LLC
Owner Address: 6300 Richmond Avenue, Suite 300
Houston, TX 77057
Owner Status: Current Owner
Purchase Date: 11/21/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/9/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/8/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041353 Brake Time IL Properties, LLC Current Owner 11/21/2024
U0039389 Minit Mart, LLC Former Owner 12/5/2018
U0026726 TA Operating, LLC Former Owner 8/13/2015
U0010459 MKM Oil, Inc. Former Owner 7/10/2007
U0010420 Minuteman of Wilmington, Inc. Former Owner 6/26/1989

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250822 (Pending)    Issue Date: 3/28/2025    Expiration Date: 5/27/2025    View NOV Form

Tanks Violation
Facility Facility Operation and Maintenance Plan not updated to new requirements. - Plan not updated with new owner's information and next test dates (pg 6,7 and 8). Form can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copy of emergency instructions or emergency procedures plan - Plan not updated with new owner information. Form can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
1, 2, 3, 4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Water in T3 and T4, leafs and garbage in T1 and T2.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1998 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/18/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/26/2024 11/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/26/2024 11/26/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 11/26/2024 11/26/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/26/2024 11/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 12/13/2023
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/26/2024



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1998 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/19/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/26/2024 11/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/26/2024 11/26/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 11/26/2024 11/26/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/26/2024 11/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/26/2024
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/13/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/11/1998 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/19/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/31/2025 3/31/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/26/2024 11/26/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 11/26/2024 11/26/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/26/2024 11/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/26/2024



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/14/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/14/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/6/2022 3/31/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/26/2024 11/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/26/2024 11/26/2025
Overfill Prev Device Overfill Drop Tube Valve 11/26/2024 11/26/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/26/2024 11/26/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/26/2024



Tank Number 5

Capacity: 2000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2008 Abandoned Material: Inert material mixed with portland cement
Current Age: 17 Abandoned Date: 5/28/2021
Install Date: 1/14/2008 Red Tag Issue Date:
Last Used Date: 6/1/2016 Fee Due: $0.00
Product Date: 1/14/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/4/2016 4/4/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/27/2020 2/27/2021
Overfill Prev Device Overfill Drop Tube Valve 6/6/2019 6/6/2022
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/6/2019 7/6/2022
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found