Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1028432
Status: Active
Facility Name: Beck's #27
Address: 1302 Raymond Drive
Mendota, IL 61342
County: LaSalle
Property Parcel: 01-25-308-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003201
Green Tag Issue Date: 6/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Beck Oil Company of Illinois
Owner Address: 850 E. Thompson St.
Princeton, IL 61356
Owner Status: Current Owner
Purchase Date: 6/27/2013
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/18/2017 12/31/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0001282 Beck Oil Company of Illinois Current Owner 6/27/2013
U0018176 Gromann's I-39, Inc./Truck Plaza Former Owner 11/24/1989

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020251141 (Pending)    Issue Date: 4/30/2025    Expiration Date: 6/29/2025    View NOV Form

Tanks Violation
1, 2, 3, 4, 5 Miscellaneous - Two ATGs are onsite. Please clarify what methods of tank leak detection are being performed and recorded by each ATG.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0498 Eligible 5/16/2014 6/30/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/17/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/30/2024 4/30/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Double Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/28/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/17/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/30/2024 4/30/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 4/28/2025 4/28/2026
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Blending Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Single Wall Transition Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Single Wall Transition Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Double Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/28/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 4/28/2025
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 5/8/2023



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/17/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/30/2024 4/30/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Blending Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Single Wall Transition Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Single Wall Transition Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Double Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/28/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 4/28/2025
Piping Flexible Double Wall A.P.T. Poly Tech P200SC Precision Test (Piping) Pass 5/8/2023



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/17/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/30/2024 4/30/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Double Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/28/2025



Tank Number 5

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/17/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/30/2024 4/30/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Double Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/28/2025



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/29/2018 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/15/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/28/2025 4/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/28/2025 4/28/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/28/2025 4/28/2026
Overfill Prev Device Overfill Alarm 4/28/2025 4/28/2028
Piping Blending Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Piping Single Wall Transition Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026
Spill Contain Device Single Wall Spill Bucket 4/28/2025 4/28/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/28/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 10 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 11/12 auto

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 12 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 13 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 14 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 15

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/5/2022 5/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/30/2024 4/30/2025



Name\ID 9/10 Auto

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/28/2025 4/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/28/2025 4/28/2026

MFD Motorfuel Dispensing Forms

No Forms Found