Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1027978
Status: Inactive
Facility Name: Circle K #4701323
Address: 6950 E. Riverside Drive Loves Park, IL 61111
County: Winnebago
Property Parcel: 12-03-278-006
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001278
Green Tag Issue Date: 3/23/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 12/30/2020
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/23/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 12/30/2020
U0030258 Kooshtard Property III, LLC Former Owner 6/21/2001
U0023515 Johnson Oil Company, L.L.C. Former Owner 12/10/1999
U0000552 BP Products North America, Inc. Former Owner 1/1/1991

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00904-2025REM Removal Approved / Issued 7/11/2025 7/15/2025 1/15/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020250406 (Referred to Legal)    Issue Date: 2/18/2025    Expiration Date: 4/19/2025    View NOV Form

Tanks Violations
1, 2, 3 Sacrificial system failed test; must repair. - Tank Cathodic Protection system has failed required testing. System shall be repaired/replaced to restore system functionality. FAILED TEST 2/11/2025
1, 2, 3 Triennial spill prevention equipment testing not completed. - Triennial inspection of spill bucket(s) has not been completed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0745 Eligible 10/20/2014 12/16/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date: 5/6/2025
Last Used Date: 5/22/2025 Fee Due: $0.00
Product Date: 1/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 2/5/2022 2/5/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2024 11/6/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 11/6/2024 11/6/2025
Overfill Prev Device Overfill Drop Tube Valve 12/4/2023 12/4/2026
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/23/2021 2/23/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/6/2024



Tank Number 2

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date: 5/6/2025
Last Used Date: 5/22/2025 Fee Due: $0.00
Product Date: 1/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 2/5/2022 2/5/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2024 11/6/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 11/6/2024 11/6/2025
Overfill Prev Device Overfill Drop Tube Valve 12/4/2023 12/4/2026
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/23/2021 2/23/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/6/2024



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date: 5/6/2025
Last Used Date: 5/22/2025 Fee Due: $0.00
Product Date: 1/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 2/5/2022 2/5/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2024 11/6/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 11/6/2024 11/6/2025
Overfill Prev Device Overfill Drop Tube Valve 12/4/2023 12/4/2026
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/23/2021 2/23/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/6/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms