Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1025344
Status: Active
Facility Name: Express Lane Gas & Food Mart
Address: 209 East North Avenue
Stockton, IL 61085
County: Jo Daviess
Property Parcel: 17-002-017-00
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02042
Green Tag Issue Date: 3/27/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Arthur J. Johnson Family Limited Partnership
Owner Address: 1305 12th Avenue
Rock Falls, IL 61071
Owner Status: Current Owner
Purchase Date: 9/15/2010
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 9/22/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/27/2025 12/31/2027
Unattended Self Service 3/21/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040750 Arthur J. Johnson Family Limited Partnership Current Owner 9/15/2010
U0008040 Johnson Oil Company Former Owner 9/15/2010
U0008265 Kappes Standard Ser Former Owner 2/3/1998
U0023834 BP Amoco Former Owner 10/24/1997
U0026381 Dillon-Dillon, Inc. Former Owner 2/2/1997
U0008265 Kappes Standard Ser Former Owner 12/31/1967
U0034691 ZB Group of Companies, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
892103 10/23/1989 Removal Log
981006 4/30/1998 Removal Log

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/1998
OSFM First Notify Date: 3/15/1990 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 11/10/1989 Red Tag Issue Date:
Last Used Date: 4/1/1998 Fee Due: $0.00
Product Date: 11/10/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/1998
OSFM First Notify Date: 3/15/1990 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 11/2/1989 Red Tag Issue Date:
Last Used Date: 4/1/1998 Fee Due: $0.00
Product Date: 11/2/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/1998
OSFM First Notify Date: 3/15/1990 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 11/2/1989 Red Tag Issue Date:
Last Used Date: 4/1/1998 Fee Due: $0.00
Product Date: 11/2/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/1998
OSFM First Notify Date: 3/15/1990 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 2/1/1987 Red Tag Issue Date:
Last Used Date: 4/1/1998 Fee Due: $0.00
Product Date: 2/10/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 5/6/1998
OSFM First Notify Date: 8/22/1997 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1967 Red Tag Issue Date:
Last Used Date: 1/1/1990 Fee Due: $0.00
Product Date: 1/2/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1989
OSFM First Notify Date: 4/23/1990 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1989
OSFM First Notify Date: 4/23/1990 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/6/1998
OSFM First Notify Date: 4/23/1990 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1967 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/2/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/6/1998
OSFM First Notify Date: 4/23/1990 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1967 Red Tag Issue Date:
Last Used Date: 1/1/1990 Fee Due: $0.00
Product Date: 1/1/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/6/1998
OSFM First Notify Date: 4/23/1990 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1967 Red Tag Issue Date:
Last Used Date: 1/1/1990 Fee Due: $0.00
Product Date: 1/2/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/16/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/30/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/30/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/10/2024 8/10/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/10/2024 8/10/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/10/2024 8/10/2025
Overfill Prev Device Overfill Alarm 9/10/2022 9/10/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/10/2022 9/10/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2024 8/10/2025
Spill Contain Device Single Wall Spill Bucket 9/10/2022 9/10/2025
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/10/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 8/30/2019



Tank Number 12

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/16/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/30/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/30/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/10/2024 8/10/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/10/2024 8/10/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/10/2024 8/10/2025
Overfill Prev Device Overfill Alarm 9/10/2022 9/10/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/10/2022 9/10/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2024 8/10/2025
Spill Contain Device Single Wall Spill Bucket 9/10/2022 9/10/2025
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/10/2024



Tank Number 13

Capacity: 8200 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/16/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/30/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/30/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/10/2024 8/10/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/10/2024 8/10/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/10/2024 8/10/2025
Overfill Prev Device Overfill Alarm 9/10/2022 9/10/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/10/2022 9/10/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2024 8/10/2025
Spill Contain Device Single Wall Spill Bucket 9/10/2022 9/10/2025
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/10/2024



Tank Number 14

Capacity: 8200 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/16/1998 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/30/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/30/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/10/2024 8/10/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/10/2024 8/10/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/10/2024 8/10/2025
Overfill Prev Device Overfill Alarm 9/10/2022 9/10/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/10/2022 9/10/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2024 8/10/2025
Spill Contain Device Single Wall Spill Bucket 9/10/2022 9/10/2025
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/10/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found