Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1020673
Status: Active
Facility Name: Oregon BP
Address: 108 E. Washington Street
Oregon, IL 61061
County: Ogle
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001883
Green Tag Issue Date: 9/8/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Oregon Sales & Service, Inc.
Owner Address: 108 E. Washington Street
Oregon, IL 61061
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 3/20/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/10/2024 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032205 Oregon Sales & Service, Inc. Current Owner
U0032155 Gill & Patel, LLC Former Owner 6/22/2004
U0007721 J & L Oil Co., Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0492 6/15/2010 Removal Log 00578-2010REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
10-0492 Eligible 8/23/2010 10/7/2010 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/1/2009 12/1/2010
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/1/2009 12/1/2010
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/1/2009 12/1/2010
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/1/2009 12/1/2010
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 12/14/2009 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/18/2007 10/18/2008
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/15/2010
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/15/1998 12/15/2003
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/1/2009 12/1/2010
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 12/1/2009



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/20/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 4/4/2024 4/4/2027
Overfill Prev Device Overfill Drop Tube Valve 4/4/2024 4/4/2027
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Double Wall STP/Tanktop Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Chase Secondary Containment OPW Geoduct non-corrosive flexible secondary piping Precision Test (Piping) Pass 4/7/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 9/19/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 4/7/2021



Tank Number 8

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/20/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 4/4/2024 4/4/2027
Overfill Prev Device Overfill Drop Tube Valve 9/4/2024 9/4/2027
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Double Wall STP/Tanktop Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Chase Secondary Containment OPW Geoduct non-corrosive flexible secondary piping Precision Test (Piping) Pass 4/7/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 9/19/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 4/7/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 4/3/2023



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/20/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 4/4/2024 4/4/2027
Overfill Prev Device Overfill Drop Tube Valve 4/4/2024 4/4/2027
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Double Wall STP/Tanktop Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Chase Secondary Containment OPW Geoduct non-corrosive flexible secondary piping Precision Test (Piping) Pass 4/7/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 9/19/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 4/7/2021



Tank Number 10

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/20/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 4/4/2024 4/4/2027
Overfill Prev Device Overfill Drop Tube Valve 4/4/2024 4/4/2027
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Double Wall STP/Tanktop Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Chase Secondary Containment OPW Geoduct non-corrosive flexible secondary piping Precision Test (Piping) Pass 4/7/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 9/19/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 4/7/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 1/19/2022 1/19/2025
Leak Detect - Piping Sump Sensor 9/19/2024 9/19/2025

MFD Motorfuel Dispensing Forms

No Forms Found