Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1017934
Status: Active
Facility Name: Casey's General Store #1248
Address: 138 East Main Street
Highway 6 & 34
Wyanet, IL 61379
County: Bureau
Property Parcel: 15-16-356-021
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002276
Green Tag Issue Date: 9/1/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 8/1/1985
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/1/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 8/1/1985

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00372-2024UPG Upgrade Approved / Issued 4/3/2024 4/3/2024 10/3/2024 Documents

Deficiencies (Current)

NOV Number: E0020240891 (Pending)    Issue Date: 3/21/2024    Expiration Date: 5/20/2024    View NOV Form

Tanks Deficiency
1, 2 Ball float vent valve(s) failed inspection; remove ball float vent valve(s).
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Tank 2 STP sump lid cracked and handle is broken, repair or replace. Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated or missing, the cover and supporting components that are defective shall be replaced.
Facility Missing list of designated Class A/B & C Operators
2 Triennial testing for qualifying piping containment sump not completed (Required every 3 years).
1, 2 Water in dispenser containment with interstitial sensors - Remove water and repair containments to prevent water ingress - Liquid was found in both STP's and Dispensor 1/2.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-1086 Eligible 11/18/2004 12/6/2004 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 8/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/30/2023 11/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 11/30/2023 11/30/2024
Overfill Prev Device Ball Float Vent Valve EBW 308 12/17/2020 12/17/2023
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 11/30/2023 11/30/2026
Leak Detect - Piping Sump Sensor 11/30/2023 11/30/2024
Spill Contain Device Single Wall Spill Bucket 11/30/2023 11/30/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 8/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/30/2023 11/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 11/30/2023 11/30/2024
Overfill Prev Device Ball Float Vent Valve EBW 308 12/17/2020 12/17/2023
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 3/30/2020 3/30/2023
Leak Detect - Piping Sump Sensor 11/30/2023 11/30/2024
Spill Contain Device Single Wall Spill Bucket 11/30/2023 11/30/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/30/2023 11/30/2026
Leak Detect - Piping Sump Sensor 11/30/2023 11/30/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/30/2023 11/30/2026
Leak Detect - Piping Sump Sensor 11/30/2023 11/30/2024

MFD Motorfuel Dispensing Forms