Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1012095
Status: Active
Facility Name: Starved Rock Marina
Address: 1130 N 27th Road Ottawa, IL 61350
County: LaSalle
Property Parcel: 19-24-107-000
Facility Type: Marina
Owner Type: Private
Green Tag Decal: Z001866
Green Tag Issue Date: 7/9/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Marina

Owner Details

Owner Name: Bumpus Boating, LLC
Owner Address: 708 Somonauk Street Sycamore, IL 60178
Owner Status: Current Owner
Purchase Date: 3/24/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/2/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040169 Bumpus Boating, LLC Current Owner 3/24/2021
U0014470 Starved Rock Marina Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261500 (Pending)    Issue Date: 6/9/2026    Expiration Date: 8/8/2026    View NOV Form

Tanks Violations
Facility Missing copies of 30 day Walkthrough Inspection Report. - An A/B certified operator is required to do the 30-Day walkthoughs. Either the person currently doing these inspections needs to re-certify or the current AB needs to begn conducting these inspections.
Facility Missing copy of emergency instructions or emergency procedures plan - Left blank onsite
Facility Missing copy of written UST facility operation & maintenance plan - Left blank onsite

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/10/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/10/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/10/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/20/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/10/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/2/1996 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 4/22/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/22/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/22/2026 5/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 5/22/2026 5/22/2027
Overfill Prev Device Overfill Drop Tube Valve 5/22/2026 5/22/2029
Piping Flexible Double Wall Ameron Flex III Not applicable Not applicable
Piping Flexible Double Wall A.P.T. Poly Tech MarinaFlex metallic ducted Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/22/2026 5/22/2029
Leak Detect - Piping Stand Alone Sump Sensor 5/22/2026 5/22/2029
Piping Single Wall Transition Sump 5/22/2026 5/22/2029
Spill Contain Device Single Wall Spill Bucket 5/22/2026 5/22/2029
Tank Fiberglass Single Wall Owens Corning Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech MarinaFlex metallic ducted Precision Test (Piping) Pass 5/22/2026
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 5/22/2026
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 9/11/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 4/20/2011



Tank Number 6

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/2/1996 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 4/22/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/22/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/22/2026 5/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 5/22/2026 5/22/2027
Overfill Prev Device Overfill Drop Tube Valve 5/22/2026 5/22/2029
Piping Flexible Double Wall A.P.T. Poly Tech P100SC Not applicable Not applicable
Piping Flexible Double Wall Ameron Flex III Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/22/2026 5/22/2029
Leak Detect - Piping Stand Alone Sump Sensor 5/22/2026 5/22/2029
Piping Single Wall Transition Sump 5/22/2026 5/22/2029
Spill Contain Device Single Wall Spill Bucket 5/22/2026 5/22/2029
Tank Fiberglass Single Wall Owens Corning Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P100SC Precision Test (Piping) Pass 5/22/2026
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 5/22/2026
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 9/11/2020
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 4/20/2011

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID Dock 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/22/2026 5/22/2029
Leak Detect - Piping Stand Alone Sump Sensor 5/22/2026 5/22/2027



Name\ID Dock 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/22/2026 5/22/2029
Leak Detect - Piping Stand Alone Sump Sensor 5/22/2026 5/22/2027



Name\ID Land

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found